Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Araştırmacılar
  • Projeler
  • Birimler
  • Analiz
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Adams, Dave" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Yayın
    Design of the near infrared camera DIRAC for East Anatolia Observatory
    (SPIE, 2022) Zhelem, Ross; Content, Robert; Churilov, Vladimir; Kripak, Yevgen; Waller, Lew; Case, Scott; Mali, Slavko; Muller, Rolf; Gonzalez, Mario; Adams, Dave; Binos, Nick; Chin, Timothy; Farrell, Tony; Klauser, Urs; Kondrat, Yuriy; Kunwar, Nirmala; Lawrence, Jon; Lorente, Nuria; Luo, Summer; McDonald, Erica; McGregor, Helen; Nichani, Vijay; Pai, Naveen; Vuong, Minh; Zahoor, Jahanzeb; Zheng, Jessica; Norris, Barnaby; Bryant, Julia; Vaccarella, Annino; Herrald, Nick; Gilbert, James; Yeşilyaprak, Cahit; Güçsav, Bülent; Coker, Deniz; Keskin, Onur; Jolissaint, Laurent
    The 4m DAG telescope is under construction at East Anatolia Observatory in Turkey. DIRAC, the " DAG InfraRed Adaptive optics Camera", is one of the facility instruments. This paper describes the design of the camera to meet the performance specifications. Adaptive and auxiliary optics relay the telescope F/14 input 1:1 into DIRAC. The camera has an all refractive design for the wavelength range 0.9 - 2.4 micron. Lenses reimage the telescope focal plane 33 x 33 as (9 x 9 mm) on a 1k x 1k focal plane array. With magnification of 2x, the plate scale on the detector is 33 mas/pixel. There are 4 standard filters (Y, J, H, K) and 4 narrowband continuum filters. A 12 position filter wheel allows installation of 2 extra customer filters for specific needs; the filter wheel also deploys a pupil viewer lens. Optical tolerancing is carried out to deliver the required image quality at polychromatic Strehl ratio of 90% with focus compensator. This reveals some challenges in the precision assembly of optics for cryogenic environments. We require cells capable of maintaining precision alignment and keeping lenses stress free. The goal is achieved by a combination of flexures with special bonding epoxy matching closely the CTE of the lens cells and crystalline materials. The camera design is very compact with object to image distance <220 mm and lens diameters <25 mm. A standalone cryostat is LN2 cooled for vibration free operation with the bench mounted adaptive optics module (TROIA) and coronagraph (PLACID) at the Nasmyth focus of the DAG telescope.

| Işık Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Işık Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Şile, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim