Yazar "Koul, Dileep K." seçeneğine göre listele
Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
Yayın The firing temperature of pottery from ancient Mesopotamia, Turkey, using luminescence methods: a case study for different grain-size fractions(Wiley-Blackwell, 2014-10) Polymeris, George S.; Güneç Kıyak, Nafiye; Koul, Dileep K.; Kitis, GeorgeThe assessment of the firing temperature of a prehistoric pottery sample collected from ancient Mesopotamia, Turkey was studied using luminescence techniques. The methods for this estimation involved the observation of the thermal and pre-dose sensitization with various re-firing temperatures for both TL and the OSL signals. In the former case, the 110 degrees C TL peak and the rest of the glow curve were used as proxies in this study. In the framework of a first attempt to investigate the impact of grain-size dependence on the sensitization of the luminescence signals, the aforementioned study was performed with four different pottery grain-size fractions: (i) less than 60m, (ii) 60-90m, (iii) 90-180m and (iv) 180-250m. The results clearly demonstrated the firing temperature mark of approximate to 500 degrees C in for the grain size of 90-180m, whileas in the case of the lower grain-size fractiona third proxy, the ratio of the pre-dosed to the thermal sensitization, was seen to indicate the firing temperature. The remaining two grain-size fractions failed to provide any meaningful results with regard to the firing temperature estimation. The dependence of the TL characteristics on the grain size was explained in the framework of the mixed mineralogy.Yayın Investigating the thermally transferred optically stimulated luminescence source trap in fired geological quartz(Pergamon-Elsevier Science Ltd, 2014-03) Koul, Dileep K.; Patil, Pravinkumar G.; Oniya, Ebenezer O.; Polymeris, George S.The pre-dosed thermoluminescence (TL) emission of quartz has been found to be useful in retrospective dosimetry and archaeometry. Though the pre-dosed optically stimulated luminescence (OSL) and emissions have been reported to be similar, the former has been found to be un-reliable for the equivalent dose estimation. As this measurement protocol involves thermal heating at around 400 degrees C, the work reported in this paper investigated the influence of this heating on the OSL using fired specimens from various regions. The results suggested that the discrepancy in the behaviour of two emissions is caused by the presence of the thermally transferred optically stimulated luminescence (TT-OSL) induced by thermal-activation involved in the pre-dose treatment. This transferred signal was observed to be very significant in the case of samples containing a prominent higher-temperature TL peak at similar to 375 degrees C. The characterization of this signal based on (i) the nature of the glow curves, (ii) thermal-annealing of the OSL trap, (iii) observation of the TT-OSL, (iv) bleaching of the source trap and (v) the correlation between TL and OSL seems to suggest that the trap corresponding to this TL peak is the source trap in the TT-OSL emission mechanism.Yayın Investigating the thermally transferred optically stimulated luminescence source trap in fired geological quartz (vol 62, pg 60, 2014)(Pergamon-Elsevier Science Ltd, 2014-08) Koul, Dileep K.; Patil, Pravinkumar G.; Oniya, Ebenezer O.; Polymeris, George S.[No abstract available]