Thermally assisted OSL from deep traps in Al2O3:C
dc.authorid | 0000-0002-9972-429X | |
dc.authorid | 0000-0001-6245-644X | |
dc.authorid | 0000-0002-8890-1895 | |
dc.contributor.author | Polymeris, George S. | en_US |
dc.contributor.author | Raptis, Spyridoula | en_US |
dc.contributor.author | Afouxenidis, Dimitrios | en_US |
dc.contributor.author | Tsirliganis, Nestor C. | en_US |
dc.contributor.author | Kitis, George | en_US |
dc.date.accessioned | 2015-01-15T23:01:36Z | |
dc.date.available | 2015-01-15T23:01:36Z | |
dc.date.issued | 2010-03 | |
dc.department | Işık Üniversitesi, Fen Edebiyat Fakültesi, Fizik Bölümü | en_US |
dc.department | Işık University, Faculty of Arts and Sciences, Department of Physics | en_US |
dc.description.abstract | The present work suggests an alternative experimental method in order to not only measure the signal of the deep traps in Al2O3:C without heating the sample to temperatures greater than 500 degrees C, but also use this signal for high dose level dosimetry purposes as well. This method consists of photo transfer OSL measurements performed at elevated temperatures using the blue LEDs (470 nm, FWHM 20 nm) housed at commercial Riso TL/OSL systems, after the sample was previously heated up to 500 degrees C in order to empty its main TL dosimetric trap. The influence of this procedure on specific features such as glow curve shape and sensitivity of the main TL glow peak was also studied. | en_US |
dc.description.version | Publisher's Version | en_US |
dc.identifier.citation | Polymeris, G., Raptis, S., Afouxenidis, D., Tsirliganis, N., & Kitis, G. (2010). Thermally assisted OSL from deep traps in Al2O3:C. Radiation Measurements, 45(3-6), 519-522. doi:10.1016/j.radmeas.2009.12.024 | en_US |
dc.identifier.doi | 10.1016/j.radmeas.2009.12.024 | |
dc.identifier.endpage | 522 | |
dc.identifier.issn | 1350-4487 | |
dc.identifier.issn | 1879-0925 | |
dc.identifier.issue | 3-6 | |
dc.identifier.issue | SI | |
dc.identifier.scopus | 2-s2.0-77955303424 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 519 | |
dc.identifier.uri | https://hdl.handle.net/11729/376 | |
dc.identifier.uri | http://dx.doi.org/10.1016/j.radmeas.2009.12.024 | |
dc.identifier.volume | 45 | |
dc.identifier.wos | WOS:000279183200077 | |
dc.identifier.wosquality | Q2 | |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | Science Citation Index Expanded (SCI-EXPANDED) | en_US |
dc.indekslendigikaynak | Conference Proceedings Citation Index – Science (CPCI-S) | en_US |
dc.institutionauthor | Polymeris, George S. | |
dc.institutionauthorid | 0000-0002-9972-429X | |
dc.language.iso | en | en_US |
dc.peerreviewed | Yes | en_US |
dc.publicationstatus | Published | en_US |
dc.publisher | Pergamon-Elsevier Science Ltd | en_US |
dc.relation.ispartof | Radiation Measurements | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Al2O3:C | en_US |
dc.subject | Aluminum | en_US |
dc.subject | Blue LEDs | en_US |
dc.subject | Deep traps | en_US |
dc.subject | Dosimetry | en_US |
dc.subject | Elevated temperature | en_US |
dc.subject | Experimental methods | en_US |
dc.subject | Glow curve | en_US |
dc.subject | Glow peaks | en_US |
dc.subject | Heating | en_US |
dc.subject | High dose levels | en_US |
dc.subject | Luminescence | en_US |
dc.subject | Luminescence OSL | en_US |
dc.subject | Mechanism | en_US |
dc.subject | Photo transfer | en_US |
dc.subject | Phototransfer | en_US |
dc.subject | Thermoluminescence | en_US |
dc.subject | TL | en_US |
dc.title | Thermally assisted OSL from deep traps in Al2O3:C | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- 376.pdf
- Boyut:
- 617.44 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Publisher's Version