Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results
Yükleniyor...
Dosyalar
Tarih
2007
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
IEEE
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
This paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric 24 transmit and 32 receive ring arrays built on the same silicon substrate. This configuration has the potential for Independent optimization of each array and uses the silicon area more effectively without any drawback. For imaging experiments, we designed and constructed a custom integrated circuit using a standard 0.5 mu m CMOS process for data acquisition. A sample pulse-echo signal received from the oil-air Interface (plane reflector) at 6mm had a center frequency of 11MHz with 95% fractional 6-dB bandwidth. The measured SNR of the echo was 24 dB with no averaging. B-scan image of a wire-phantom was generated to test the resolution.
Açıklama
Anahtar Kelimeler
A-center, Annular rings, Application specific integrated circuits, Bandwidth, Beamforming, Biomedical electronics, Biomedical transducers, Biomedical ultrasonics, Blood vessels, Bonding, Bondpads, B-scan image, Capacitive micromachined, Capacitive micromachined ultrasound transducer design, Capacitive sensors, CMOS integrated circuits, CMOS process, CMOS processing, CMUT, Data acquisition, Dual-annular ring CMUT array, Electronics industry, Forward-looking IVUS imaging, Frequency, Frequency 11 MHz, Image resolution, Imaging experiments, Imaging systems, Integrated circuit measurements, Integrated circuits, Intravascular ultrasound, Intravascular ultrasound imaging, Lithography, Microsensors, Nonmetals, Oil-air, Oil-air interface, Phantoms, Plane reflector, Pulse echoes, Pulse-echo signal, Receive ring arrays, Ring arrays, Si, Silicon, Silicon area, Silicon substrates, Size 0.5 mum, Standards, Testing, Transmit ring arrays, Ultrasonic imaging, Ultrasonic transducer arrays, Ultrasonic transducers, Ultrasonics, Wire phantom
Kaynak
2007 IEEE Ultrasonics Symposium Proceedings
WoS Q Değeri
N/A
Scopus Q Değeri
N/A
Cilt
Sayı
Künye
Güldiken, R., Zahorian, J., Gürün, G., Qureshi, M. S., Balantekin, M., Tekeş, C., . . . Değertekin, F. L. (2007). Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results. Paper presented at the 2007 IEEE Ultrasonics Symposium Proceedings, 1247-1250. doi:10.1109/ULTSYM.2007.313