Phased subarray imaging for low-cost, wideband coherent array imaging

Yükleniyor...
Küçük Resim

Tarih

2003

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

IEEE

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Araştırma projeleri

Organizasyon Birimleri

Dergi sayısı

Özet

The front-end hardware complexity of conventional full phased array (FPA) imaging is proportional to the number of array elements. Phased subarray (PSA) imaging has been proposed as a method of reducing the hardware complexity-and therefore system cost and size-while achieving near-FPA image quality. A new method is presented for designing the subarray-dependent interpolation filters suitable for wideband PSA imaging. The method was tested experimentally using pulse-echo data of a wire target phantom acquired using a 3.2-cm. 128-element capacitive micromachined ultrasonic transducer (CMUT) array with 85% fractional bandwidth at 3 MHz. A specific PSA configuration using seven 32-element subarrays was compared to FPA imaging, representing a 4-fold reduction in front-end hardware complexity and a 43% decrease in frame rate. For targets near the fixed transmit focal distance, the mean 6-dB lateral resolution was identical to that of FPA, the axial resolution improved by 4%, and the SNR decreased by 5 dB. Measurements were repeated for 10 different PSA configurations with subarray sizes ranging from 4 to 60. The lateral and axial resolutions did not vary significantly with subarray size; both the SNR and contrast-to-noise ratio (CNR) improved with increased subarray size.

Açıklama

Anahtar Kelimeler

3 MHz, 3.2 cm, Antenna phased arrays, Axial resolution, Bandwidth, Beamforming, Capacitive micromachines ultrasonic transducer, Contrast-to-noise ratio, Cost effectiveness, Costs, Filters, Flow imaging, FPA imaging, Front-end hardware complexity, Full phased array, Full phased array (FPA), Hardware, Image quality, Image resolution, Imaging, Imaging systems, Interpolation, Interpolation filters, Lateral resolution, Low cost array imaging, Nyquist diagrams, Phantoms, Phased arrays, Phased subarray imaging, Pulse-echo data, Signal to noise ratio, SNR, Subarray-dependent interpolation filters, System cost, System size, Testing, Transducers, Transmit focal distance, Ultrasonic imaging, Ultrasonic transducer arrays, Ultrasonic transducers, Wideband, Wideband coherent array imaging, Wire target phantom

Kaynak

Proceedings of the IEEE Ultrasonics Symposium

WoS Q Değeri

N/A

Scopus Q Değeri

N/A

Cilt

2

Sayı

Künye

Johnson, J. A., Oralkan, O., Ergun, A. S., Demirci, U., Karaman, M., & Khuri-Yakub, B. T. (2003). Phased subarray imaging for low-cost, wideband coherent array imaging. Paper presented at the Proceedings of the IEEE Ultrasonics Symposium, 2, 1875-1878. doi:10.1109/ULTSYM.2003.1293280