Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE)
dc.authorid | 0000-0002-4368-2238 | |
dc.authorid | 0000-0001-9198-8525 | |
dc.contributor.author | Güldiken, Rasim Oytun | en_US |
dc.contributor.author | Zahorian, Jaime S. | en_US |
dc.contributor.author | Karaman, Mustafa | en_US |
dc.contributor.author | Değertekin, Fahrettin Levent | en_US |
dc.date.accessioned | 2019-08-31T12:10:23Z | |
dc.date.accessioned | 2019-08-05T16:05:02Z | |
dc.date.available | 2019-08-31T12:10:23Z | |
dc.date.available | 2019-08-05T16:05:02Z | |
dc.date.issued | 2007 | |
dc.department | Işık Üniversitesi, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü | en_US |
dc.department | Işık University, Faculty of Engineering, Department of Electrical-Electronics Engineering | en_US |
dc.description.abstract | We designed and fabricated a 64 element 1-D linear dual electrode Capacitive Micromachined Ultrasonic Transducer (CMUT) array operating at 9.5 MHz for Intracardiac Echocardiography (ICE). The dual electrode CMUT structure increases the overall sensitivity by 12.6dB (6.2dB in receive sensitivity; 6.4dB in output pressure) when compared to optimized single electrode CMUT. We report peak output pressure of 2.3MPa on the CMUT surface when 170V AC and 180V DC is applied. This significant performance increase makes the CMUT more competitive with their piezoelectric counterparts. | en_US |
dc.description.version | Publisher's Version | en_US |
dc.identifier.citation | Güldiken, R. O., Zahorian, J. S., Karaman, M. & Değertekin, F. L. (2007). Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE). Paper presented at the 2, 349-350. doi:10.1115/IMECE2007-42480 | en_US |
dc.identifier.doi | 10.1115/IMECE2007-42480 | |
dc.identifier.endpage | 350 | |
dc.identifier.isbn | 791842967 | |
dc.identifier.isbn | 9780791842966 | |
dc.identifier.scopus | 2-s2.0-44249127754 | |
dc.identifier.scopusquality | N/A | |
dc.identifier.startpage | 349 | |
dc.identifier.uri | https://hdl.handle.net/11729/2003 | |
dc.identifier.uri | https://dx.doi.org/10.1115/IMECE2007-42480 | |
dc.identifier.volume | 2 | |
dc.identifier.wos | WOS:000254463900054 | |
dc.identifier.wosquality | N/A | |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | Conference Proceedings Citation Index – Science (CPCI-S) | en_US |
dc.institutionauthor | Karaman, Mustafa | en_US |
dc.language.iso | en | en_US |
dc.peerreviewed | Yes | en_US |
dc.publicationstatus | Published | en_US |
dc.publisher | American Society of Mechanical Engineers (ASME) | en_US |
dc.relation.ispartof | ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE) | en_US |
dc.relation.ispartofseries | ASME | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Capacitance | en_US |
dc.subject | Capacitive micromachined | en_US |
dc.subject | Capacitive micromachined ultrasonic transducer | en_US |
dc.subject | Dual electrode capacitive micromachined ultrasonic transducer arrays | en_US |
dc.subject | Dual electrodes | en_US |
dc.subject | Echocardiography | en_US |
dc.subject | Electrodes | en_US |
dc.subject | Intracardiac echocardiographies | en_US |
dc.subject | Intracardiac Echocardiography (ICE) | en_US |
dc.subject | Micromachining | en_US |
dc.subject | Optimization | en_US |
dc.subject | Pressure | en_US |
dc.subject | Sensitivity analysis | en_US |
dc.subject | Single electrodes | en_US |
dc.subject | Transducers | en_US |
dc.subject | Ultrasonic imaging | en_US |
dc.subject | Ultrasonic transducers | en_US |
dc.title | Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE) | en_US |
dc.type | Conference Object | en_US |
dspace.entity.type | Publication |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- 2003.pdf
- Boyut:
- 75.56 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Publisher's Version