Damariçi yanal kesit görüntüleme için farklı prob yapılarının incelenmesi
dc.authorid | 0000-0002-2239-9927 | |
dc.contributor.author | Şişman, Alper | en_US |
dc.contributor.author | Karaman, Mustafa | en_US |
dc.date.accessioned | 2015-07-14T23:48:11Z | |
dc.date.available | 2015-07-14T23:48:11Z | |
dc.date.issued | 2009-06-26 | |
dc.department | Işık Üniversitesi, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü | en_US |
dc.department | Işık University, Faculty of Engineering, Department of Electrical-Electronics Engineering | en_US |
dc.description | We thank the anonymous referees for his/her valuable comments. This work is supported in part by JSPS Grant-in-Aid for Scientific Research (B) (No. 25287062) 'Probing the origin of primordial mini-halos via gravitational lensing phenomena'. The work of TT is partially supported by the Grant-in-Aid for Scientific Research from the Ministry of Education, Science, Sports, and Culture, Japan, No. 23740195. TI is financially supported by MEXT HPCI Strategic Program and MEXT/JSPS KAKENHI Grant Number 24740115. Numerical computations were carried out on Cray XT4 at Center for Computational Astrophysics, CfCA, at National Astronomical Observatory of Japan and the K computer at the RIKEN Advanced Institute for Computational Science (proposal numbers hp120286 and hp130026). | en_US |
dc.description.abstract | Bu çalışmada dönen bir şaftın yanal yüzeyine yerleştirilmiş 8 adet içiçe halka elemanlardan oluşan yana bakan görüntüleme için yeni bir kateter yapısı incelenmiştir. Bu Katater mimarisi basit bir dizi önü alıcı verici elektroniği ile değişken odaklama olanağı sağlamaktadır. Önerilen mimari, mevcut iki farklı kateter mimarisiyle benzetim sonuçları ile karşılaştırmalı olarak incelenmiştir. Benzetimlerde görüntüleme kateter çapı 1mm alınmış, farklı derinlikler ve açılar için 3 noktasal yansıtıcı ile NDF çıkarılmıştır. | en_US |
dc.description.abstract | We investigated a side-looking catheter structure employing rotating annular array with 8 concentric annuli.. This structure allows dynamic focusing with a simple front-end electronic. We tested the image quality of proposed structure using simulations and compared with the existing structures. | en_US |
dc.description.sponsorship | MEXT HPCI Strategic Program | en_US |
dc.description.sponsorship | Japan Society for the Promotion of Science | en_US |
dc.description.sponsorship | Ministry of Education, Culture, Sports, Science and Technology | en_US |
dc.description.version | Publisher's Version | en_US |
dc.identifier.citation | Şişman, A. & Karaman, M. (2009). Analysis of catheter-based imaging devices for side-looking IVUS. Paper presented at the 2009 14th National Biomedical Engineering Meeting, 251-254. doi:10.1109/BIYOMUT.2009.5130312 | en_US |
dc.identifier.doi | 10.1109/BIYOMUT.2009.5130312 | |
dc.identifier.endpage | 254 | |
dc.identifier.isbn | 9781424436057 | |
dc.identifier.isbn | 9781424436064 | |
dc.identifier.scopus | 2-s2.0-84869644996 | |
dc.identifier.scopusquality | N/A | |
dc.identifier.startpage | 251 | |
dc.identifier.uri | https://hdl.handle.net/11729/630 | |
dc.identifier.uri | http://dx.doi.org/10.1109/BIYOMUT.2009.5130312 | |
dc.identifier.wos | WOS:000274345400064 | |
dc.identifier.wosquality | N/A | |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | Conference Proceedings Citation Index – Science (CPCI-S) | en_US |
dc.institutionauthor | Şişman, Alper | en_US |
dc.institutionauthor | Karaman, Mustafa | en_US |
dc.institutionauthorid | 0000-0002-2239-9927 | |
dc.language.iso | tr | en_US |
dc.peerreviewed | Yes | en_US |
dc.publicationstatus | Published | en_US |
dc.publisher | IEEE | en_US |
dc.relation.ispartof | 2009 14th National Biomedical Engineering Meeting | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Annular array | en_US |
dc.subject | Biomedical engineering | en_US |
dc.subject | Biomedical optical imaging | en_US |
dc.subject | Capacitive micromachined | en_US |
dc.subject | Catheter-based imaging | en_US |
dc.subject | Catheters | en_US |
dc.subject | Concentric annuli | en_US |
dc.subject | Dynamic focusing | en_US |
dc.subject | Existing structure | en_US |
dc.subject | Focusing | en_US |
dc.subject | Front end electronics | en_US |
dc.subject | Front-End electronic | en_US |
dc.subject | Gaussian processes | en_US |
dc.subject | Image analysis | en_US |
dc.subject | Image quality | en_US |
dc.subject | Imaging devices | en_US |
dc.subject | Rotating annular array | en_US |
dc.subject | Side-looking | en_US |
dc.subject | Side-Looking catheter structure | en_US |
dc.subject | Side-Looking IVUS | en_US |
dc.subject | Testing | en_US |
dc.subject | Transducers | en_US |
dc.subject | Ultrasonic imaging | en_US |
dc.subject | Ultrasonic transducers | en_US |
dc.title | Damariçi yanal kesit görüntüleme için farklı prob yapılarının incelenmesi | en_US |
dc.title.alternative | Analysis of catheter-based imaging devices for side-looking IVUS | en_US |
dc.type | Conference Object | en_US |
dspace.entity.type | Publication |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- 630.pdf
- Boyut:
- 1.19 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Publisher's Version