Dual-annular-ring CMUT array for forward-looking IVUS imaging
dc.authorid | 0000-0002-4368-2238 | |
dc.authorid | 0000-0003-0685-3584 | |
dc.authorid | 0000-0001-9198-8525 | |
dc.authorid | 0000-0002-2357-4424 | |
dc.authorid | 0000-0002-2239-9927 | |
dc.contributor.author | Güldiken, Rasim Oytun | en_US |
dc.contributor.author | Zahorian, Jaime | en_US |
dc.contributor.author | Balantekin, Müjdat | en_US |
dc.contributor.author | Değertekin, Fahrettin Levent | en_US |
dc.contributor.author | Tekeş, Coşkun | en_US |
dc.contributor.author | Şişman, Alper | en_US |
dc.contributor.author | Karaman, Mustafa | en_US |
dc.date.accessioned | 2019-08-31T12:10:23Z | |
dc.date.accessioned | 2019-08-05T16:03:07Z | |
dc.date.available | 2019-08-31T12:10:23Z | |
dc.date.available | 2019-08-05T16:03:07Z | |
dc.date.issued | 2006 | |
dc.department | Işık Üniversitesi, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü | en_US |
dc.department | Işık University, Faculty of Engineering, Department of Electrical-Electronics Engineering | en_US |
dc.description | This research is funded by NIH-NHLBI (Grant No: 1 R01 HL082811-01) and Boston Scientific Corp. Support of Isik University through the internal grant BAP-05B301 is also acknowledged. | en_US |
dc.description.abstract | We investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same silicon substrate. This configuration has the potential for independent optimization of each array and uses the silicon area more effectively without any particular drawback. We designed and fabricated a 1mm diameter test array which consists of 24 transmit and 32 receive elements. We investigated synthetic phased array beamforming with a non-redundant subset (if transmit-receive element pairs of the dual-annular-ring array. For imaging experiments, we designed and constructed a programmable FPGA-based data acquisition and phased array beamforming system. Pulse-echo measurements along with imaging simulations suggest that dual-ring-annular array should provide performance suitable for real-time FLAVUS applications. | en_US |
dc.description.sponsorship | This research is funded by NIH-NHLBI (Grant No: 1 R01 HL082811-01) and Boston Scientific Corp. Support of Isik University through the internal grant BAP-05B301 is also acknowledged. | en_US |
dc.description.sponsorship | United States Department of Health & Human Services | en_US |
dc.description.sponsorship | National Institutes of Health (NIH) - USA | en_US |
dc.description.sponsorship | NIH National Heart Lung & Blood Institute (NHLBI) | en_US |
dc.description.sponsorship | Boston Scientific Corp. Support of Isik University | en_US |
dc.description.version | Publisher's Version | en_US |
dc.identifier.citation | Güldiken, R. O., Zahorian, J., Balantekin, M., Değertekin, F. L., Tekeş, C., Şişman, A. & Karaman, M. (2006). Dual-Annular-Ring CMUT Array for Forward-Looking IVUS Imaging. Paper presented at the 698-701. doi:10.1109/ULTSYM.2006.187 | en_US |
dc.identifier.doi | 10.1109/ULTSYM.2006.187 | |
dc.identifier.endpage | 701 | |
dc.identifier.isbn | 9781424402014 | |
dc.identifier.isbn | 1424402018 | |
dc.identifier.isbn | 1424402026 | |
dc.identifier.issn | 1051-0117 | |
dc.identifier.scopus | 2-s2.0-44949169778 | |
dc.identifier.scopusquality | N/A | |
dc.identifier.startpage | 698 | |
dc.identifier.uri | https://hdl.handle.net/11729/1823 | |
dc.identifier.uri | https://dx.doi.org/10.1109/ULTSYM.2006.187 | |
dc.identifier.volume | 1 | |
dc.identifier.wos | WOS:000260407800167 | |
dc.identifier.wosquality | N/A | |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | Conference Proceedings Citation Index – Science (CPCI-S) | en_US |
dc.institutionauthor | Tekeş, Coşkun | en_US |
dc.institutionauthor | Şişman, Alper | en_US |
dc.institutionauthor | Karaman, Mustafa | en_US |
dc.institutionauthorid | 0000-0002-2357-4424 | |
dc.institutionauthorid | 0000-0002-2239-9927 | |
dc.language.iso | en | en_US |
dc.peerreviewed | Yes | en_US |
dc.publicationstatus | Published | en_US |
dc.publisher | IEEE | en_US |
dc.relation.ispartof | 2006 IEEE Ultrasonics Symposium, Vols 1-5, Proceedings | en_US |
dc.relation.ispartofseries | Ultrasonics Symposium | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | 1 mm | en_US |
dc.subject | Annular array | en_US |
dc.subject | Array signal processing | en_US |
dc.subject | Array configurations | en_US |
dc.subject | Beamforming | en_US |
dc.subject | Biomedical ultrasonics | en_US |
dc.subject | Capacitive micromachined | en_US |
dc.subject | Capacitive micromachined ultrasonic transducers | en_US |
dc.subject | CMUT | en_US |
dc.subject | Data acquisition | en_US |
dc.subject | Dual annular ring CMUT array | en_US |
dc.subject | Dual-ring | en_US |
dc.subject | Field programmable gate array | en_US |
dc.subject | FL-IVUS imaging | en_US |
dc.subject | Forward looking IVUS imaging | en_US |
dc.subject | FPGA based data acquisition system | en_US |
dc.subject | Imaging experiments | en_US |
dc.subject | Imaging simulation | en_US |
dc.subject | Imaging systems | en_US |
dc.subject | Intravascular ultrasound | en_US |
dc.subject | Intravascular ultrasound imaging | en_US |
dc.subject | IVUS imaging | en_US |
dc.subject | Micromechanical devices | en_US |
dc.subject | Phased array beamforming system | en_US |
dc.subject | Phased arrays | en_US |
dc.subject | Pulse echoes | en_US |
dc.subject | Pulse measurements | en_US |
dc.subject | Pulse-echo measurements | en_US |
dc.subject | Real time FL-IVUS applications | en_US |
dc.subject | Ring arrays | en_US |
dc.subject | Silicon | en_US |
dc.subject | Silicon area | en_US |
dc.subject | Silicon substrate | en_US |
dc.subject | Silicon substrates | en_US |
dc.subject | Syhnthetic phased array | en_US |
dc.subject | Synthetic phased array beamforming | en_US |
dc.subject | Test arrays | en_US |
dc.subject | Testing | en_US |
dc.subject | Transmit-receive ring arrays | en_US |
dc.subject | Ultrasonic imaging | en_US |
dc.subject | Ultrasonic transducer arrays | en_US |
dc.subject | Ultrasonic transducers | en_US |
dc.subject | Ultrasonics | en_US |
dc.title | Dual-annular-ring CMUT array for forward-looking IVUS imaging | en_US |
dc.type | Conference Object | en_US |
dspace.entity.type | Publication |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- 1823.pdf
- Boyut:
- 589.93 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Publisher's Version