7 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 7 / 7
Yayın Evaluation of CMUT annular arrays for side-looking IVUS(IEEE, 2009) Şişman, Alper; Zahorian, Jaime S.; Gürün, Gökçe; Karaman, Mustafa; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Hasler, Paul E.Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single rotating piezoelectric transducer have simple front-end, but have fixed focused operation, and suffers from motion artifacts. Solid-state SL-IVUS imaging probes use piezoelectric transducer arrays and electronic beam-forming. Synthetic phased array processing of signals detected with small-sized elements in these arrays limits the SNR achievable with these probes. In this study, we explore a new SL-IVUS probe architecture employing rotating phased annular CMUT arrays. We tested and compared imaging performance of the existing and proposed probe configurations through simulated point spread functions. We also two fabricated sample annular array designs operating at 20-MHz and 50-MHz. Our experimental measurements on the 20-MHz array in oil shows 105% fractional bandwidth. The 50-MHz array with parylene coating shows approximately 40% fractional bandwidth measured in water. We also present imaging results acquired from wire-targets to test the experimental point-spread functions.Yayın Damariçi yanal kesit görüntüleme için farklı prob yapılarının incelenmesi(IEEE, 2009-06-26) Şişman, Alper; Karaman, MustafaBu çalışmada dönen bir şaftın yanal yüzeyine yerleştirilmiş 8 adet içiçe halka elemanlardan oluşan yana bakan görüntüleme için yeni bir kateter yapısı incelenmiştir. Bu Katater mimarisi basit bir dizi önü alıcı verici elektroniği ile değişken odaklama olanağı sağlamaktadır. Önerilen mimari, mevcut iki farklı kateter mimarisiyle benzetim sonuçları ile karşılaştırmalı olarak incelenmiştir. Benzetimlerde görüntüleme kateter çapı 1mm alınmış, farklı derinlikler ve açılar için 3 noktasal yansıtıcı ile NDF çıkarılmıştır.Yayın Subarray delta-sigma beamforming for ultrasonic imaging(IEEE, 2002) Bilge, Hasan Şakir; Karaman, MustafaWe present a beamforming architecture based on subarray processing with non-uniform oversampling 1-bit delta-sigma (??) modulation. The subarray processing combines conventional phased array and synthetic aperture approaches to form a large aperture using small subarrays thus reduces active channel count. ??-based beamforming improves the efficiency of front-end processing further: oversampling permits precise delaying and single bit data processing simplifies beamforming operation. To reduce the number of firings we use a low beam density associated with the subarray size, and then increase the beam density by lateral interpolation prior to coherent beam summation. Our experimental test results show that the proposed scheme provides high-resolution beamforming while simplifying the front-end.Yayın Annular CMUT arrays for side looking intravascular ultrasound imaging(IEEE, 2007) Zahorian, Jaime; Güldiken, Rasim Oytun; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Carlier, Stephane; Şişman, Alper; Karaman, MustafaAlthough side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements in transducer performance are needed to perform harmonic imaging and high resolution imaging of vulnerable plaque. With their small channel count; annular arrays exploiting the inherent broad bandwidth of CMUTs and electronic focusing capability of integrated electronics provide a path for desired SL-IVUS imaging catheters. In this paper, we first describe the design, low temperature fabrication of an 8401 mu m diameter, 8 element CMUT annular array. Testing of the individual elements in oil shows a uniform device behavior with 100% fractional bandwidth around 20MHz without including the effects of attenuation and diffraction. We also present linear scan imaging results obtained on wire targets in oil, tissue and tissue mimicking phantoms using both unfocused and dynamically focused transducers. The results for axial and lateral resolution are in agreement predicted by the simulations and show the feasibility of this approach for high resolution SL-IVUS imaging.Yayın An integrated circuit with transmit beamforming and parallel receive channels for real-time three-dimensional ultrasound imaging(IEEE, 2006) Wygant, Ira O.; Lee, Hyunjoo J.; Nikoozadeh, Amin; Yeh, David T.; Oralkan, Ömer; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasWe present the design of an integrated circuit (IC) that will be flip-chip bonded to a 16 x 16-element CMUT array. The IC provides 16 receive channels which can be configured to receive along either of the array diagonals or on any single row of the array. On transmit, all 256 elements can be used to transmit arbitrarily focused beams. Focused transmission with the full array is made possible by on-chip pulsers and memory. A 25-V pulser and 8-bit shift register is provided for each element of the array. Prior to each transmit, new values are loaded into the shift registers. Current-con trolled one-shots control the transmit pulse widths. Circuit simulations and the IC layout are presented. Simulations predict that delay values can be loaded in less than 1.3 mu s and show the generation of precisely timed pulses. The IC is being prepared for submission to National Semiconductor for fabrication in a high-voltage BiCMOS process.Yayın A tunable analog delay element for high-frequency dynamic beamforming(IEEE, 2009) Gürün, Gökçe; Şişman, Alper; Zahorian, Jaime S.; Satır, Sarp; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin LeventImplementing beamforming for high frequency arrays is challenging because of the accurate delay requirements at high frequencies. High frequency digital beamforming is not suitable for catheter based applications as a large number of cables is required between the array and the external beamformer. A possible solution is to perform analog beamforming on an integrated circuit adjacent or monolithically integrated to the imaging array. In this study, we introduce an improved voltage in voltage out low pass filter as an analog delay cell for high frequency dynamic beamformers. This circuit can generate three times more delay with a given bandwidth when compared to conventional low pass filters. Delay of the circuit is tunable and the gain of the cell is inherently very close to unity. The proposed delay cell operates single ended and therefore is more suitable for CMUT operation which generates single ended output. We designed a test beamformer for a 30MHz, equal area, annular array with 100% bandwidth using the proposed delay cell and the unit-delay focusing architecture. Required delays are implemented using a delay line made up of improved delay elements with tunable delays. To demonstrate functionality we designed and fabricated a custom front-end IC in a 0.5µm standard CMOS process. The IC chip consists of 8 transimpedance amplifiers, voltage-to-current converters, the analog dynamic beamformer, and two buffers. We present results of preliminary imaging experiments that demonstrate the focusing capability.Yayın Real-time range sensing with a Scheimpflug camera and a single custom sensor/processor chip(SPIE-Int Soc Optical Engineering, 2003) Çilingiroğlu, Uğur; Çilingiroğlu, Emre; Chen, Sicheng; Yarman, Bekir Sıddık BinboğaAn image-based range sensing technique is presented. The technique is originally considered for highway collision avoidance applications but its generality makes it suitable for application in robotics, manufacturing and metrology as well. It relies on depth from focus but, unlike conventional techniques, it extracts range with a single unmodulated Scheimpflug camera in continuous time. The range extraction algorithm is memoryless and simple enough to be implemented on the same chip with photosensors. The technique deploys a sensor plane that is tilted at a non-orthogonal angle with respect to the optical axis of the lens, and the optical axis intersects the sensor plane at the focal point. This optical arrangement creates a focusable object plane in an orientation parallel to the optical axis, and thus, enables range sensing along the same axis. The paper elaborates on the details of focus sensing on the tilted sensor plane, describes the CMOS sensor/processor chip designed and prototyped for this application, and presents experimental results.












