4 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 4 / 4
Yayın Small molecule sorption and desorption in and out of iota-carrageenan gels(Taylor & Francis Group, 2007-08) Ataman, Evren; Pekcan, Mehmet ÖnderSmall molecule sorption and desorption in and out of Iota-Carrageenan was studied by using steady-state fluorescence (SSF) technique. Pyranine dissolved in water used as fluorescence probe. Fluorescence emission intensity, I-p from pyranine was monitored for studying sorption and desorption processes at various temperatures. The Fickian model was applied to produce sorption, D-s, early desorption, D-ed, and desorption, D-d, coefficients. Corresponding activation energies were obtained and found to be 20.5 kJ mol(-1), 7.0 kJ mol(-1) and 34.9 kJ mol(-1), respectively. The observed D-ed value is an order of magnitude smaller than the D-s and D-d coefficients. On the other hand, sorption processes were shown to be twice as fast as desorption processes.Yayın Small molecule desorption from a swelling polymeric glass in polymer solution: Energy transfer method(Elsevier Science Sa, 2005-07-15) Uğur, Şaziye; Pekcan, Mehmet ÖnderDirect energy transfer (DET) method conjunction with fast transient fluorescence (FTRF) technique were used to study small molecule desorption from a swelling poly(methyl methacrylate) (PMMA) glass in polymer solution, which is consist of naphthalene (N)-labeled PMMA chains in chlorofrom-heptane mixture. Desorption coefficients, D-d of pyrene (P) desorbing from the swelling PMMA glass prior to dissolution were measured and found to be 8.3 x 10(-8) and 1.3 x 10(-5) cm(2) s(-1) in short and long time regions, respectively.Yayın Drying of PAAm hydrogels at various temperatures: A fluorescence study(Taylor & Francis Group, 2007-05) Aktaş, Demet Kaya; Evingür, Gülşen Akın; Pekcan, Mehmet ÖnderThe steady-state fluorescence (SSF) technique was employed for studying the drying of polyacrylamide (PAAm) hydrogels. Disc-shaped hydrogels were prepared by free-radical crosslinking copolymerization of acrylamide (AAm) with N,N'-methylene bisacrylamide (BIS) as crosslinker in the presence of ammonium persulfate (APS) as an initiator. Pyranine (P) was introduced as a fluorescence probe and the intensity of pyranine was monitored during in situ drying at various temperatures. It was observed that the fluorescence intensity of pyranine increased during the drying process. A supporting, gravimetrical experiment was also performed. A phenomenological equation was introduced to determine the desorption coefficient, D, of water molecules from the drying hydrogels at various temperatures. The desorption activation energy, triangle E-d, values were measured for the drying processes and found to be 91.08 and 36.82 kJ mol(-1) by fluorescence and gravimetrical methods, respectively. This difference most probably originates from the origin of the techniques; the fluorescence technique measures the parameters at a molecular level, whereas the gravimetrical technique measures a parameter in the bulk.Yayın Small molecule desorption prior to dissolution of a polymeric glass(Wiley Subscription Services, Inc., A Wiley Company, 2006-07-15) Pekcan, Mehmet Önder; Uğur, ŞaziyePoly(methyl methacrylate) (PMMA) discs in various molecular weights (M-w) were prepared by free-radical polymerization. Pyrene (Py) was introduced during polymerization as a fluorescence probe. In situ steady state fluorescence experiments were performed to monitor desorption processes in chloroform solvent. When the PMMA discs were in chloroform, desorption of Py molecules were monitored by observing the change of Py fluorescence intensity I-P. To understand the mechanism of desorption, two different experiments were carried out in the meantime. In the first experiment, the weight of swelling and dissolving PMMA discs against dissolution time was monitored. The parallel experiment was conducted by measuring fluorescence intensity I-P from the desorbing Py molecules. Then, a set of desorption experiments were performed by monitoring I-P for various discs with different molecular weight of PMMA. A Fickian diffusion model was employed to quantify the fluorescence data produced from the swelling PMMA discs to measure desorption coefficients D-d. The measured D-d values decrease as the molecular weight of PMMA is increased in the swelling glass.












