  • Yayın
    Volumetric ultrasound imaging using 2-D CMUT arrays
    (IEEE-Inst Electrical Electronics Engineers Inc, 2003-11) Oralkan, Ömer; Ergün, Arif Sanlı; Cheng, Ching-Hsiang; Johnson, Jeremy A.; Karaman, Mustafa; H. Lee, Thomas; Khuri-Yakub, Butrus Thomas
    Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128 x 128-element 2-D CMUT array with through-wafer via interconnects and a 420-mum element pitch. As an experimental prototype, a 32 x 64-element portion of the 128 X 128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16 X 16-element portion of the array to surrounding bondpads. An 8 x 16-element poition of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4 X 4 group of elements in the middle of the 8 X 16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to integrate these dense 2-D arrays with electronic circuits for practical 3-D imaging applications.
  • Yayın
    Image recovery of inaccessible rough surfaces profiles having impedance boundary condition
    (IEEE, 2022) Sefer, Ahmet; Yapar, Ali
    This letter addresses a reconstruction algorithm of locally rough inaccessible surface profiles via the knowledge of the scattered field data under the consideration of the impedance boundary condition (IBC). To this aim, first, the synthetic scattered field data are obtained through the solution of the conventional surface integral equation (SIE) written on the rough surface. Then, the same SIE together with the data equation is solved iteratively via Newton's method to obtain the image of the rough surface profile. In the numerical implementation, the nonlinear ill-posed inverse problem is linearized in an iterative fashion via the Newton method and regularized by Tikhonov in the least-squares sense. The feasibility of the algorithm is provided via numerical examples, which shows that the method is effective and promising.
  • Yayın
    Coherent array imaging using phased subarrays. Part II: Simulations and experimental results
    (IEEE-INST Electrical Electronics Engineers Inc, 2005-01) Johnson, Jeremy A.; Oralkan, Ömer; Ergün, Arif Sanlı; Demirci, Utkan; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas
    The basic principles and theory of phased subarray (PSA) imaging imaging provides the flexibility of reducing I he number of front-end hardware channels between that of classical synthetic aperture (CSA) imaging-which uses only one element per firing event-and full-phased array (FPA,) imaging-which uses all elements for each firing. The performance of PSA generally ranges between that obtained by CSA and FPA using the same array, and depends on the amount of hardware complexity reduction. For the work described in this paper, we performed FPA, CSA, and PSA imaging of a resolution phantom using both simulated and experimental data from a 3-MHz, 3.2-cm, 128-element capacitive micromachined ultrasound transducer (CMUT) array. The simulated system point responses in the spatial and frequency domains are presented as a means of studying the effects of signal bandwidth, reconstruction filter size, and subsampling rate on the PSA system performance. The PSA and FPA sector-scanned images were reconstructed using the wideband experimental data with 80% fractional bandwidth, with seven 32-element subarrays used for PSA imaging. The measurements on the experimental sector images indicate that, at the transmit focal zone, the PSA method provides a 10% improvement in the 6-dB lateral resolution, and the axial point resolution of PSA imaging is identical to that of FPA imaging. The signal-to-noise ratio (SNR) of PSA image was 58.3 dB, 4.9 dB below that of the FPA image, and the contrast-to-noise ratio (CNR) is reduced by 10%. The simulated and experimental test results presented in this paper validate theoretical expectations and illustrate the flexibility of PSA imaging as a way to exchange SNR and frame rate for simplified front-end hardware.
  • Yayın
    Minimally redundant 2-D array designs for 3-D medical ultrasound imaging
    (IEEE-Inst Electrical Electronics Engineers Inc, 2009-07) Karaman, Mustafa; Wygant, Ira O.; Oralkan, Ömer; Khuri-Yakub, Butrus Thomas
    In real-time ultrasonic 3-D imaging, in addition to difficulties in fabricating and interconnecting 2-D transducer arrays with hundreds of elements, there are also challenges in acquiring and processing data from a large number of ultrasound channels. The coarray (spatial convolution of the transmit and receive arrays) can be used to find efficient array designs that capture all of the spatial frequency content (a transmit-receive element combination corresponds to a spatial frequency) with a reduced number of active channels and firing events. Eliminating the redundancies in the transmit-receive element combinations and firing events reduces the overall system complexity and improves the frame rate. Here we explore four reduced redundancy 2-D array configurations for miniature 3-D ultrasonic imaging systems. Our approach is based on 1) coarray design with reduced redundancy using different subsets of linear arrays constituting the 2-D transducer array, and 2) 3-D scanning using fan-beams (narrow in one dimension and broad in the other dimension) generated by the transmit linear arrays. We form the overall array response through coherent summation of the individual responses of each transmit-receive array pairs. We present theoretical and simulated point spread functions of the array configurations along with quantitative comparison in terms of the front-end complexity and image quality.
  • Yayın
    Postprocessing of decoded color images by adaptive linear filtering
    (Elsevier Science, 2003-02) Bayazıt, Uluğ
    This paper presents an image adaptive linear filtering method for the reconstruction of the RGB (red, blue, green) color coordinates of a pixel from the lossy compressed luminance/chrominance color coordinates. In the absence of quantization noise, the RGB coordinates of a pixel can be perfectly reconstructed by employing a standard, fixed filter whose support includes only the luminance/chrominance coordinates at the spatial location of the pixel. However, in the presence of quantization noise, a filter with a larger support, that also spatially extends over the luminance/chrominance coordinate planes, is capable of exploiting the statistical dependence among the luminance/chrominance coordinate planes, and thereby yields more accurate reconstruction than the standard, fixed filter. We propose the optimal (in the minimum mean squared error sense) determination of the coefficients of this adaptive linear filter at the image encoder by solving a system of regression equations. When transmitted as side information to the image decoder, the filter coefficients need not incur significant overhead if they are quantized and compressed intelligently. Our simulation results demonstrate that the distortion of the decompressed color coordinate planes can be reduced by several tenths of a dB with negligible overhead rate by the application of our image adaptive linear filtering method.