8 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 8 / 8
Yayın TL and OSL response of turquoise for dosimetric application(University of Aegean, 2010) Subedi, Bhagawan; Afouxenidis, Dimitrios; Polymeris, George S.; Tsirliganis, Nestor C.; Paraskevopoulos, Konstantinos M.; Kitis, GeorgeTurquoise is one of the amongst first gem stones used in jewelry and possessing cultural value since 2000 BC (at least). This work attempts characterize this stone scientifically using both thermally (TL) and optically stimulated luminescence (OSL) techniques. The experimental investigation included 1) the study of the natural TL and OSL signals, 2) the reproducibility of TL sensitivity over repeated irradiation and TL readout cycles, 3) dependence of sensitivity on annealing temperatures and 4) the TL and OSL dose response curves. The potential use of the TL and OSL techniques in determination of provenance, accidental dosimetry and probably to authenticity and dating purposes are then discussed.Yayın Component resolved OSL dose response and sensitization of various sedimentary quartz samples(Elsevier Ltd, 2007-02) Güneç Kıyak, Nafiye; Polymeris, George S.; Kitis, GeorgeThe structure of the linearly modulated optically stimulated luminescence (LM-OSL) signal was studied for four sedimentary quartz samples, collected from different sites around Istanbul, Turkey. Applying a computerized deconvolution analysis to the LM-OSL curves, at least six individual components of first-order kinetics were identified and photoionization cross-section of each component was evaluated. The OSL dose-response curve of each component for each quartz sample was obtained, showing a remarkable differentiation from component to component. The behavior of a highly dosed sample to successive LM-OSL measurements was also studied showing a stable recuperation signal in the position of the "slow" and "medium" components and high resistance to OSL bleaching of the "slow" component. The individual sensitivity of each component as a function of the activation temperature was obtained. The sensitivity of each component was normalized over the respective sensitivity of the glow-peak at 110 degrees C of quartz in order to investigate the ability of the 110 degrees C glow-peak to act as a correction factor for all components of the LM-OSL curves examined.Yayın Thermally assisted OSL from deep traps in Al2O3:C(Pergamon-Elsevier Science Ltd, 2010-03) Polymeris, George S.; Raptis, Spyridoula; Afouxenidis, Dimitrios; Tsirliganis, Nestor C.; Kitis, GeorgeThe present work suggests an alternative experimental method in order to not only measure the signal of the deep traps in Al2O3:C without heating the sample to temperatures greater than 500 degrees C, but also use this signal for high dose level dosimetry purposes as well. This method consists of photo transfer OSL measurements performed at elevated temperatures using the blue LEDs (470 nm, FWHM 20 nm) housed at commercial Riso TL/OSL systems, after the sample was previously heated up to 500 degrees C in order to empty its main TL dosimetric trap. The influence of this procedure on specific features such as glow curve shape and sensitivity of the main TL glow peak was also studied.Yayın Effect of annealing temperature on determining trap depths of quartz by various heating rates method(Pergamon-Elsevier Science, 2001-12) Güneç Kıyak, Nafiye; Buluş, E.The aim of this study is to determine the trap parameters (trap depth E, frequency factors) of quartz using various heating rates method and also to investigate the effect of annealing temperature on determining trap depths. The method is based on the positions of the thermoluminescence peaks, obtained from the change in temperature of the peak at maximum caused by changing the heating rate at which the sample is measured. In the present work, powder quartz samples were annealed first at different temperatures before irradiation. Then samples irradiated to different doses were measured with a TL reader at different heating rates and the glow curves were recorded. In order to calculate the trap depth E and the frequency factor s, the glow parameter T-m was determined experimentally from the glow curve by measuring the shift of the maximum peak temperature depending on heating rate beta. The calculation of trap parameters was repeated for each annealing temperature. Then the effect of annealing temperature on trap depths calculated by the various heating rates method was evaluated.Yayın Luminescence ages of feldspar contaminated quartz from fluvial terrace sediments(Wind-J Wojewoda Publ Co, 2008-01-01) Güneç Kıyak, Nafiye; Erturaç, Mehmet KorhanThis study focuses on obtaining luminescence ages in feldspar contaminated quartz from well-developed fluvial terraces of the Yesilirmak (Iris) river located inside the eastern North Anatolian Fault Shear Zone (NAFZ). We applied a technique based on conventional single-aliquot regenerative-dose (SAR) protocol, modified with an IR pre-treatment to reduce the OSL contribution from feldspar for accurately measuring the dose in quartz. All investigated samples showed an ability to measure a beta dose given in the laboratory, a so called dose recovery test. The dependence of the equivalent dose on thermal treatment was also examined. Dose rate calculations were based on spectral analysis of gamma measurements by a field spectrometer on site. The efforts to establish a chronology using the IR modified SAR technique produced reliable dose results in stratigraphic order. Results were reproducible and grouped broadly between 35-109 ka for Bektemur, 32-36 ka for Kizilca, 19-47 ka for Aksalur and 35-44 ka for Sahinkaya. Obtained results show that the studied area was controlled by tectonic activities within the last 50 ka and the sample Aksalur 2 was the loess deposit formed by aeolian activity.Yayın TL/OSL properties of crystalline inclusions from heavy, barytes loaded, concrete(Pergamon-Elsevier Science Ltd, 2010-03) Güneç Kıyak, Nafiye; Polymeris, George S.; Kitis, GeorgeIn the present work, we report the luminescence data obtained from heavy, barytes loaded, concrete containing many crystalline inclusions, extracted from a shielding block located at CERN. The use of both Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) signals, resulting from a specific trap at about 200 degrees C, is investigated for retrospective dosimetry purposes. By applying thermal cleaning experiments the TL signal of interest was isolated. Basic TL and OSL properties as thermal and optical stability, repeatability and mainly the linearity of the TL and OSL signals as a function of beta dose were investigated. The implications of all these luminescence properties to retrospective dosimetry are also briefly discussed.Yayın Thermoluminescence and optically stimulated luminescence properties of natural barytes(Elsevier Ltd, 2010-12) Kitis, George; Güneç Kıyak, Nafiye; Polymeris, George S.Heavy, baryte-loaded, concrete is commonly used as radiation shielding material around high energy particle accelerators. Concrete samples received from a shielding block located at CERN cite contain many crystalline inclusions which were identified as barytes by X-ray diffraction analysis and separated by their color, classified as white, orange and green. Basic properties of thermoluminescence (TL) and optically stimulated luminescence (OSL) signals of these barytes samples such as thermal and optical stability, repeatability and mainly the linearity of both their luminescence responses were investigated as a function of beta dose These results are also discussed regarding detailed investigation on the correlation between TL and OSL signals and their implications for retrospective dosimetryYayın Investigation of OSL signals from very deep traps in unfired and fired quartz samples(Elsevier Science BV, 2010-03-15) Kitis, George; Güneç Kıyak, Nafiye; Polymeris, George S.; Pagonis, VasilisThis paper presents an attempt to isolate experimentally optically stimulated luminescence (OSL) signals which may originate from very deep traps (VDT) in quartz samples. As VDT we consider those traps which are responsible for TL glow peaks with a peak maximum temperature above a TL readout temperature of 500 C. The basic experimental procedure used to isolate OSL signals from VDT is heating the quartz samples to 500 C immediately before measuring the OSL signal. The study was carried out on eight quartz samples of very different origins; it is found that all eight samples exhibit OSL signals from VDT, and for a wide region of OSL stimulation temperatures. The OSL signal from VDT depends strongly on the type of quartz sample studied and on whether the sample was fired at high temperatures or not. The behavior of the OSL signal from VDT as a function of the stimulation temperature is found to be very different in fired and unfired samples. The thermal activation energy E for the OSL signals from VDT is obtained in both fired and unfired samples. The OSL signal from VDT in quartz samples fired at 800 C for 1 h is very high, and the OSL curves consist of three well-defined components and a fourth slow component which is rather poorly resolved. The dose response of these components is obtained using a computerized deconvolution procedure for the dose region 0.5-300 Gy. The results are of importance for dating of ancient fired ceramics, since OSL signals from VDT could potentially extend appreciably the equivalent dose region toward both lower and higher values.












