17 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 10 / 17
Yayın Integrated ultrasonic imaging systems based on CMUT arrays: Recent progress(IEEE, 2004) Wygant, Ira O.; Zhuang, Xuefeng; Yeh, David T.; Nikoozadeh, Amin; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasThis paper describes the development of an ultrasonic imaging system based on a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array. The transducer array and front-end electronics are designed to fit in a 5-mm endoscopic channel. A custom-designed integrated circuit, which comprises the front-end electronics, will be connected with the transducer elements via through-wafer interconnects and flip-chip bonding. FPGA-based signal-processing hardware will provide real-time three-dimensional imaging. The imaging system is being developed to demonstrate a means of integrating the front-end electronics with the transducer array and to provide a clinically useful technology. Integration of the electronics can improve signal-to-noise ratio, reduce the number of cables connecting the imaging probe to a separate processing unit, and provide a means of connecting electronics to large two-dimensional transducer arrays. This paper describes the imaging system architecture and the progress we have made on implementing each of its components: a 16×16 CMUT array, custom-designed integrated circuits, a flip-chip bonding technique, and signal-processing hardware.Yayın Volumetric ultrasound imaging using 2-D CMUT arrays(IEEE-Inst Electrical Electronics Engineers Inc, 2003-11) Oralkan, Ömer; Ergün, Arif Sanlı; Cheng, Ching-Hsiang; Johnson, Jeremy A.; Karaman, Mustafa; H. Lee, Thomas; Khuri-Yakub, Butrus ThomasRecently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128 x 128-element 2-D CMUT array with through-wafer via interconnects and a 420-mum element pitch. As an experimental prototype, a 32 x 64-element portion of the 128 X 128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16 X 16-element portion of the array to surrounding bondpads. An 8 x 16-element poition of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4 X 4 group of elements in the middle of the 8 X 16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to integrate these dense 2-D arrays with electronic circuits for practical 3-D imaging applications.Yayın CMUT-based volumetric ultrasonic imaging array design for forward looking ICE and IVUS applications(SPIE-Int Soc Optical Engineering, 2013) Tekeş, Coşkun; Zahorian, Jaime S.; Xu, Toby; Rashid, Muhammad Wasequr; Satır, Sarp; Gürün, Gökçe; Karaman, Mustafa; Hasler, Jennifer Olson; Değertekin, Fahrettin LeventDesigning a mechanically flexible catheter based volumetric ultrasonic imaging device for intravascular and intracardiac imaging is challenging due to small transducer area and limited number of cables. With a few parallel channels, synthetic phased array processing is necessary to acquire data from a large number of transducer elements. This increases the data collection time and hence reduces frame rate and causes artifacts due to tissue-transducer motion. Some of these drawbacks can be resolved by different array designs offered by CMUT-on-CMOS approach. We recently implemented a 2.1-mm diameter single chip 10 MHz dual ring CMUT-on-CMOS array for forward looking ICE with 64-transmit and 56-receive elements along with associated electronics. These volumetric arrays have the small element size required by high operating frequencies and achieve sub mm resolution, but the system would be susceptible to motion artifacts. To enable real time imaging with high SNR, we designed novel arrays consisting of multiple defocused annular rings for transmit aperture and a single ring receive array. The annular transmit rings are utilized to act as a high power element by focusing to a virtual ring shaped line behind the aperture. In this case, image reconstruction is performed by only receive beamforming, reducing total required firing steps from 896 to 14 with a trade-off in image resolution. The SNR of system is improved more than 5 dB for the same frequency and frame rate as compared to the dual ring array, which can be utilized to achieve the same resolution by increasing the operating frequency.Yayın Decoder-side super-resolution and frame interpolation for improved H.264 video coding(IEEE, 2013) Ateş, Hasan FehmiIn literature decoder-side motion estimation is shown to improve video coding efficiency of both H.264 and HEVC standards. In this paper we introduce enhanced skip and direct modes for H.264 coding using decoder-side super-resolution (SR) and frame interpolation. P-and B-frames are downsampled and H.264 encoded at lower resolution (LR). Then reconstructed LR frames are super-resolved using decoder-side motion estimation. Alternatively for B-frames, bidirectional true motion estimation is performed to synthesize a B-frame from its reference frames. For P-frames, bicubic interpolation of the LR frame is used as an alternative to SR reconstruction. A rate-distortion optimal mode selection algorithm determines for each MB which of the two reconstructions to use as skip/direct mode prediction. Simulations indicate an average of 1.04 dB PSNR improvement or 23.0% bitrate reduction at low bitrates when compared to H.264 standard. Average PSNR gains reach as high as 3.95 dB depending on the video content and frame rate.Yayın A novel computed tomography image compression method based on classified energy and pattern blocks(IEEE, 2013) Gökbay, İnci Zaim; Gezer, Murat; Güz, Ümit; Gürkan, Hakan; Yarman, Bekir Sıddık BinboğaIn this work, a new biomedical image compression method is proposed based on the classified energy and pattern blocks (CEPB). CEPB based compression method is specifically applied on the Computed Tomography (CT) images and the evaluation results are presented. Essentially, the CEPB is uniquely designed and structured codebook which is located on the both the transmitter and receiver part of a communication system in order to implement encoding and decoding processes. The encoding parameters are block scaling coefficient (BSC) and the index numbers of energy (IE) and pattern blocks (IP) determined for each block of the input images based on the CEPB. The evaluation results show that the newly proposed method provides considerable image compression ratios and image quality.Yayın Image recovery of inaccessible rough surfaces profiles having impedance boundary condition(IEEE, 2022) Sefer, Ahmet; Yapar, AliThis letter addresses a reconstruction algorithm of locally rough inaccessible surface profiles via the knowledge of the scattered field data under the consideration of the impedance boundary condition (IBC). To this aim, first, the synthetic scattered field data are obtained through the solution of the conventional surface integral equation (SIE) written on the rough surface. Then, the same SIE together with the data equation is solved iteratively via Newton's method to obtain the image of the rough surface profile. In the numerical implementation, the nonlinear ill-posed inverse problem is linearized in an iterative fashion via the Newton method and regularized by Tikhonov in the least-squares sense. The feasibility of the algorithm is provided via numerical examples, which shows that the method is effective and promising.Yayın Spektral yöntemler ve küme bölüntüleme yaklaşımlarıyla 3B nesne bilgilerinin sıkıştırılması(IEEE, 2006) Konur, Umut; Bayazıt, Uluğ; Gürgen, Sadık Fikret; Orcay, ÖzgürSpekral dönüşümle elde edilen katsayıları küme bölüntüleme yaklaşımlarıyla işleyerek 3B nesne geometrilerini kodlayan bir yöntem öneriyoruz. [1]' de anlatılan spektral yöntem düzensiz tel filelerde yüksek hız-bozunum başarımı sağlamakla kalmayıp, geriçatımı, katsayı vektörünü kırparak elde edilen ve toplam enerjisinin büyük bir bölümünü taşıyan alt vektörüyle gerçekleştirdiği için aşamalı iletim de sağlayabilmektedir. Önerilen spektral yöntemde, nesne geometrisinin [1]' de olduğu gibi topolojiden türetilen birimdik bir taban üzerine izdüşümü alınmakta ve elde edilen katsayılar [2]' nin küme bölüntüleme algoritmasıyla kodlanmaktadır. Yöntem üç koordinata ait spektral katsayılara dolaylı bit ataması başardığı ve önemli katsayılara ait konum bilgisini bu katsayıların bit düzlemlerindeki sıfırlarını birleşik kodlayarak verimli kodlama sağladığı için, yaygın düzensiz tel fileler üzerinde yaptığımız deneylerde [1]' e göre daha iyi hız-bozunum başarımı vermektedir. Üretilen bit katarı da tamamen gömülüdür.Yayın Damar içi öne bakan ultrasonik görüntüleme için eşdeğer dizi örnekleme yöntemleri(IEEE, 2009-06-26) Tekeş, Coşkun; Karaman, MustafaDamar içi öne bakan ultrasonik görüntüleme gerçek zamanlı hacimsel (üç boyutlu) görüntülemeye imkan vermesi bakımından yaygın olarak kullanılmaktadır. Damar içi görüntülemede fiziksel boyutların küçük olması nedeniyle alıcı-verici kanal sayısı çok sınırlanmakta ve dolayısıyla yapay evreli dizi teknikleri kullanılmaktadır. Öte yandan, harekete bağlı görüntü bozukluklarını azaltmak için işaret gönderme alma adım sayısının azaltılması gerekmektedir. Bu, eşdeğer dizideki fazlalık frekans bileşenleri azaltılarak sağlanabilir. Bu çalışmada, eşdeğer dizideki fazlalık frekans bileşenlerinin azaltılmasına dayalı farklı örnekleme teknikleri incelenmiştir. Bu tekniklerin görüntü kalitesi 64 elemanlı bir halkasal dizinin asıl ve kontrol eşdeğer dizileri referans alınarak karşılaştırmalı olarak irdelenmiştir. Benzetim sonuçları 64 elemanlı bir halka dizi için 2049 asıl küme, 350 azaltılmış küme 40 dB içinde eşdeğer performans vermektedir.Yayın Coherent array imaging using phased subarrays. Part II: Simulations and experimental results(IEEE-INST Electrical Electronics Engineers Inc, 2005-01) Johnson, Jeremy A.; Oralkan, Ömer; Ergün, Arif Sanlı; Demirci, Utkan; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasThe basic principles and theory of phased subarray (PSA) imaging imaging provides the flexibility of reducing I he number of front-end hardware channels between that of classical synthetic aperture (CSA) imaging-which uses only one element per firing event-and full-phased array (FPA,) imaging-which uses all elements for each firing. The performance of PSA generally ranges between that obtained by CSA and FPA using the same array, and depends on the amount of hardware complexity reduction. For the work described in this paper, we performed FPA, CSA, and PSA imaging of a resolution phantom using both simulated and experimental data from a 3-MHz, 3.2-cm, 128-element capacitive micromachined ultrasound transducer (CMUT) array. The simulated system point responses in the spatial and frequency domains are presented as a means of studying the effects of signal bandwidth, reconstruction filter size, and subsampling rate on the PSA system performance. The PSA and FPA sector-scanned images were reconstructed using the wideband experimental data with 80% fractional bandwidth, with seven 32-element subarrays used for PSA imaging. The measurements on the experimental sector images indicate that, at the transmit focal zone, the PSA method provides a 10% improvement in the 6-dB lateral resolution, and the axial point resolution of PSA imaging is identical to that of FPA imaging. The signal-to-noise ratio (SNR) of PSA image was 58.3 dB, 4.9 dB below that of the FPA image, and the contrast-to-noise ratio (CNR) is reduced by 10%. The simulated and experimental test results presented in this paper validate theoretical expectations and illustrate the flexibility of PSA imaging as a way to exchange SNR and frame rate for simplified front-end hardware.Yayın Compression of the CT images using classified energy and pattern blocks(IEEE, 2013) Gökbay, İnci Zaim; Gezer, Murat; Güz, Ümit; Gürkan, Hakan; Yarman, Bekir Sıddık BinboğaIn this work, a new biomedical image compression method is proposed based on the classified energy and pattern blocks (CEPB). CEPB based compression method is specifically applied on the Computed Tomography (CT) images and the evaluation results are presented. Essentially, the CEPB is uniquely designed and structured codebook which is located on the both the transmitter and receiver part of a communication system in order to implement encoding and decoding processes. The encoding parameters are block scaling coefficient (BSC) and the index numbers of energy (IE) and pattern blocks (IP) determined for each block of the input images based on the CEPB. The evaluation results show that the newly proposed method provides considerable image compression ratios and image quality.












