Arama Sonuçları

Listeleniyor 1 - 2 / 2
  • Yayın
    An inverse source problem connected with thermoacoustic imaging in multi-layer planar medium
    (Springer, 2019-02-20) Yücel, Hazel; Ünalmış Uzun, Banu
    We derived analytical forward and inverse solution of thermoacoustic wave equation for nonhomogeneous medium. We modelled the nonhomogeneous medium as a multi-layer planar medium and defined initial conditions, continuity conditions on the layer boundaries and radiation conditions at infinity assuming the source distribution existing in all layers. These solutions of thermoacoustic wave equation are based on the method of Green’s functions for layered planar media. For qualitative testing and comparison of the point-spread functions associated with the homogeneous and layered solutions, we performed numerical simulations. Our simulation results showed that the conventional inverse solution based on homogeneous medium assumption, as expected, produced incorrect locations of point sources, whereas our inverse solution involving the multi-layer planar medium produced point sources at the correct source locations. Also, we examined whether the performance of our layered inverse solution is sensitive to medium parameters used as priority information in the measured data. Our inverse solutions based on multi-layer planar media are applicable for cross-sectional two-dimensional imaging of abdominal structure and the organs such as breast and skin.
  • Yayın
    Forward-viewing CMUT arrays for medical Imaging
    (IEEE-INST Electrical Electronics Engineers Inc, 2004-07) Demirci, Utkan; Ergün, Arif Sanlı; Oralkan, Ömer; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas
    This paper reports the design and testing of forward-viewing annular arrays fabricated using capacitive micromachined ultrasonic transducer (CMUT) technology. Recent research studies have shown that CMUTs have broad frequency bandwidth and high-transduction efficiency. One- and two-dimensional CMUT arrays of various sizes already have been fabricated, and their viability for medical imaging applications has been demonstrated. We fabricated 64-element, forward-viewing annular arrays using the standard CMUT fabrication process and carried out experiments to measure the operating frequency, bandwidth, and transmit/receive efficiency of the array elements. The annular array elements, designed for imaging applications in the 20 MHz range, had a resonance frequency of 13.5 MHz in air. The immersion pulse-echo data collected from a plane reflector showed that the devices operate in the 5-26 MHz range with a fractional bandwidth of 135%. The output pressure at the surface of the transducer was measured to be 24 kPa/V. These values translate into a dynamic range of 131.5 dB for I-V excitation in 1-Hz bandwidth with a commercial low noise receiving circuitry. The designed, forward-viewing annular CMUT array is suitable for mounting on the front surface of a cylindrical catheter probe and can provide Doppler information for measurement of blood flow and guiding information for navigation through blood vessels in intravascular ultrasound imaging.