16 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 10 / 16
Yayın Investigating the thermally transferred optically stimulated luminescence source trap in fired geological quartz(Pergamon-Elsevier Science Ltd, 2014-03) Koul, Dileep K.; Patil, Pravinkumar G.; Oniya, Ebenezer O.; Polymeris, George S.The pre-dosed thermoluminescence (TL) emission of quartz has been found to be useful in retrospective dosimetry and archaeometry. Though the pre-dosed optically stimulated luminescence (OSL) and emissions have been reported to be similar, the former has been found to be un-reliable for the equivalent dose estimation. As this measurement protocol involves thermal heating at around 400 degrees C, the work reported in this paper investigated the influence of this heating on the OSL using fired specimens from various regions. The results suggested that the discrepancy in the behaviour of two emissions is caused by the presence of the thermally transferred optically stimulated luminescence (TT-OSL) induced by thermal-activation involved in the pre-dose treatment. This transferred signal was observed to be very significant in the case of samples containing a prominent higher-temperature TL peak at similar to 375 degrees C. The characterization of this signal based on (i) the nature of the glow curves, (ii) thermal-annealing of the OSL trap, (iii) observation of the TT-OSL, (iv) bleaching of the source trap and (v) the correlation between TL and OSL seems to suggest that the trap corresponding to this TL peak is the source trap in the TT-OSL emission mechanism.Yayın The correlation of fast OSL component with the TL peak at 325 degrees C in quartz of various origins(Elsevier Science BV, 2010-02) Kitis, George; Güneç Kıyak, Nafiye; Polymeris, George S.; Tsirliganis, Nestor C.The fast component of the optically stimulated luminescence (OSL) signal in quartz is the basic tool for the optical dating. Its relation with the thermoluminescence (TL) glow-peak at about 325 degrees C is well established for naturally irradiated quartz. This relationship is also an important part of a general model for quartz on which many theoretical simulations of various OSL experimental results have been based. In the present work this relationship is systematically investigated in nine quartz samples of different origin. The linearly modulated OSL (LM-OSL) curves of all quartz samples for stimulation time less than 50s consists of two components discriminated easily by a computerized curve deconvolution (CCD) analysis. By comparing the un-bleached to the respective bleached TL glow-curve, it is found that the system of these two fast OSL components is directly related with only a small portion of the electron traps responsible for the TL glow-peaks in the temperature region 200-400 degrees C. By increasing the stimulation times, besides the two fast components, the medium and the slow components are also obtained. The medium and slow components are clearly related with the main body of the electron traps responsible for TL glow-peaks in the same temperature region 200-400 degrees C. Despite their different origin all quartz samples show an appreciable homogeneity concerning the number and time position of the individual components, whereas, the relative TL/OSL intensities vary strongly from sample to sample with the integrated TL intensity being generally much less than the integrated OSL intensity.Yayın The firing temperature of pottery from ancient Mesopotamia, Turkey, using luminescence methods: a case study for different grain-size fractions(Wiley-Blackwell, 2014-10) Polymeris, George S.; Güneç Kıyak, Nafiye; Koul, Dileep K.; Kitis, GeorgeThe assessment of the firing temperature of a prehistoric pottery sample collected from ancient Mesopotamia, Turkey was studied using luminescence techniques. The methods for this estimation involved the observation of the thermal and pre-dose sensitization with various re-firing temperatures for both TL and the OSL signals. In the former case, the 110 degrees C TL peak and the rest of the glow curve were used as proxies in this study. In the framework of a first attempt to investigate the impact of grain-size dependence on the sensitization of the luminescence signals, the aforementioned study was performed with four different pottery grain-size fractions: (i) less than 60m, (ii) 60-90m, (iii) 90-180m and (iv) 180-250m. The results clearly demonstrated the firing temperature mark of approximate to 500 degrees C in for the grain size of 90-180m, whileas in the case of the lower grain-size fractiona third proxy, the ratio of the pre-dosed to the thermal sensitization, was seen to indicate the firing temperature. The remaining two grain-size fractions failed to provide any meaningful results with regard to the firing temperature estimation. The dependence of the TL characteristics on the grain size was explained in the framework of the mixed mineralogy.Yayın New quartz technique for OSL dating of limestones(2010) Liritzis, Ioannis; Drivaliari, N.; Polymeris, George S.; Katagas, Christos G.The equivalent dose De determination of limestone-made ancient constructions by thermoluminescence (TL) prevents accurate measurements and requires plateau test of bleached curves. Optical stimulated luminescence (OSL) of quartz and feldspar minerals for surface dating is routinely applied for De but not for limestones. Here the OSL of present traces of such minerals removed with powder from surface limestone bleached by sunlight overcomes this issue and offers an alternative way for De. This is verified with further test examples.Yayın Thermoluminescence as a probe in bioactivity studies; the case of 58S sol-gel bioactive glass(IOP Publishing Ltd, 2011-10-05) Polymeris, George S.; Goudouri, Ourania Menti; Kontonasaki, Eleana; Paraskevopoulos, Konstantinos M.; Tsirliganis, Nestor C.; Kitis, GeorgeThe formation of a carbonated hydroxyapatite (HCAp) layer on the surface of bioactive materials is the main reaction that takes place upon their immersion in physiological fluids. To date, all techniques used for the identification of this HCAp formation are rather time consuming and not well suited to detailed and rapid monitoring of changes in the bioactivity response of the material. The aim of this work is to explore the possibility of using thermoluminescence (TL) for the discrimination between different bioactive responses in the case of the 58S bioactive glass. Results provided strong indications that the 110 degrees C TL peak of quartz can be used effectively in the study of the bioactive behaviour of 58S bioactive glass, since it is unambiguously present in all samples and does not require deconvolution analysis. Furthermore, the intensity of the 110 degrees C TL peak is proven to be very sensitive to the different bioactive responses, identifying the loss of silica which takes place at the first stages of the sequence. The discontinuities of the 110 degrees C TL peak intensity plot versus immersion time at 8 and 1440 min provide experimental indications regarding the timescale for both the beginning of amorphous CaP formation as well as the end of crystalline hydroxyl-apatite formation respectively, while the spike in the sensitization of the 110 degrees C TL peak, which was observed for immersion times ranging between 20 and 40 min, could be an experimental feature indicating the beginning of the crystalline HCAp formation.Yayın Thermally assisted OSL from deep traps in Al2O3:C(Pergamon-Elsevier Science Ltd, 2010-03) Polymeris, George S.; Raptis, Spyridoula; Afouxenidis, Dimitrios; Tsirliganis, Nestor C.; Kitis, GeorgeThe present work suggests an alternative experimental method in order to not only measure the signal of the deep traps in Al2O3:C without heating the sample to temperatures greater than 500 degrees C, but also use this signal for high dose level dosimetry purposes as well. This method consists of photo transfer OSL measurements performed at elevated temperatures using the blue LEDs (470 nm, FWHM 20 nm) housed at commercial Riso TL/OSL systems, after the sample was previously heated up to 500 degrees C in order to empty its main TL dosimetric trap. The influence of this procedure on specific features such as glow curve shape and sensitivity of the main TL glow peak was also studied.Yayın Effect of annealing temperature on determining trap depths of quartz by various heating rates method(Pergamon-Elsevier Science, 2001-12) Güneç Kıyak, Nafiye; Buluş, E.The aim of this study is to determine the trap parameters (trap depth E, frequency factors) of quartz using various heating rates method and also to investigate the effect of annealing temperature on determining trap depths. The method is based on the positions of the thermoluminescence peaks, obtained from the change in temperature of the peak at maximum caused by changing the heating rate at which the sample is measured. In the present work, powder quartz samples were annealed first at different temperatures before irradiation. Then samples irradiated to different doses were measured with a TL reader at different heating rates and the glow curves were recorded. In order to calculate the trap depth E and the frequency factor s, the glow parameter T-m was determined experimentally from the glow curve by measuring the shift of the maximum peak temperature depending on heating rate beta. The calculation of trap parameters was repeated for each annealing temperature. Then the effect of annealing temperature on trap depths calculated by the various heating rates method was evaluated.Yayın In-homogeneity in the pre-dose sensitization of the 110 degrees C TL peak in various quartz samples: The influence of annealing(Elsevier Science BV, 2012-03-01) Polymeris, George S.; Oniya, Ebenezer O.; Jibiri, Nnamdi N.; Tsirliganis, Nestor C.; Kitis, GeorgeThe pre-dose sensitization effect of the 110 degrees C TL glow-peak of quartz is a basic tool in thermoluminescence and optically stimulated luminescence dating and retrospective dosimetry. In the present work, a homogeneity study was performed on pre-dose sensitization in grains obtained from large quartz crystals samples collected from 10 different origins. The aliquot - to - aliquot scatter of the pre-dose sensitization of the 110 degrees C TL peak within each quartz crystal was monitored. The influence of the annealing on this scattering was also studied. Therefore, the investigation was applied to the un-fired "as is" samples as well as to samples annealed at 900 degrees C for 1 h following cooling to room temperature in air. The results showed that in the case of "as is" quartz the sensitization effect vary strongly within each aliquot of the same quartz sample. This strong variation is removed by both the high temperature annealing as well as heating up to 500 degrees C, involved in the TL measurements. These results are generally discussed in the framework of existing models and applications of the effect.Yayın Dissolution and subsequent re-crystallization as zeroing mechanism, thermal properties and component resolved dose response of salt (NaCl) for retrospective dosimetry(Pergamon-Elsevier Science Ltd, 2011-09) Polymeris, George S.; Kitis, George; Güneç Kıyak, Nafiye; Sfamba, Ioanna; Subedi, Bhagawan; Pagonis, VasilisIn the present study we report dosimetric properties of iodized salt aiming at using it as an accidental luminescent dosimeter. It was found that the very good sensitivity of its main dosimetric peak is strongly affected by thermal treatments. This is also the case for OSL emission. The sensitivity loss due to heating implies that caution should be exercised while applying single aliquot protocols for dose evaluation. The sequence of dissolution and subsequent re-crystallization was established to be an extremely effective zeroing mechanism for the TL signal. The linearity in the dose response was also monitored in the case of dissolved and subsequently re-crystallized salt. In the case of naturally occurring salt, zeroing of the TL signal due to dissolution as well as the linearity of dose response up to doses as large as 100 Gy were found to be very promising features for dating applications.Yayın Luminescence dating of prehistoric site of smintheion (Gulpinar) in NW Turkey(Univ Agean, Dept Mediterranean Stud, 2010) Güneç Kıyak, Nafiye; Takaoğlu, Turan; Erginal, Ahmet Evren; Özcan, HalilThis study aims to place the prehistoric settlement of Smintheion in northwestern Turkey in its temporal setting on the basis of the dating of the quartz from pottery and sediments collected from the site employing Optically Stimulated Luminescence and Thermoluminescence techniques. The site belongs to the problematic Middle Chalcolithic period in western Anatolia. This period represents a cultural upheaval in western Anatolia as it has a completely different material culture when compared to that of the preceding Early Chalcolithic period. The pottery and sediment samples were collected from two different locations of the Middle Chalcolithic settlement at Smintheion for dating study. The fact that this examined settlement is represented by a single cultural level provides an opportunity to obtain secure and reliable dates for the settlement. Results of this study show that the site can be dated to a period between 4800 and 4500 B.C.












