Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging

Yükleniyor...
Küçük Resim

Tarih

2006-02

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

IEEE

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Araştırma projeleri

Organizasyon Birimleri

Dergi sayısı

Özet

In this study, a 64-element, 1.15-mm diameter annular-ring capacitive micromachined ultrasonic transducer (CMUT) array was characterized and used for forward-looking intravascular ultrasound (IVUS) imaging tests. The array was manufactured using low-temperature processes suitable for CMOS electronics integration oil a single chip. The measured radiation pattern of a 43 X 140- mu m(2) array element depicts a 40 degrees view angle for forward-looking imaging around a 15-MHz center frequency in agreement with theoretical models. Pulse-echo measurements show a -10-dB fractional bandwidth of 104% around 17 MHz for wire targets 2.5 mm away from the array in vegetable oil. For imaging and SNR measurements, RF A-scan data sets from various targets were collected using all interconnect scheme forming a 32-element array configuration. An experimental point spread function was obtained and compared with simulated and theoretical array responses, showing good agreement. Therefore, this study demonstrates that annular-ring CMUT arrays fabricated with CMOS-compatible processes are capable of forward-looking IVUS imaging, and the developed modeling tools can be used to design improved IVUS imaging arrays.

Açıklama

Anahtar Kelimeler

Micromachined ultrasonic transducers, Intravascular ultrasound, Pattern, Capacitive micromachined ultrasonic transducer (CMUT), Imaging arrays, Intravascular ultrasound (IVUS), Arrays, Bandwidth, CMOS integrated circuits, Mathematical models, Ultrasonic imaging, Ultrasonic transducers, Article, Computer assisted diagnosis, Endoscopic echography, Equipment, Equipment design, Evaluation, Image enhancement, Instrumentation, Methodology, Reproducibility, Sensitivity and specificity, Transducer, Equipment design, Equipment failure analysis, Image enhancement, Image interpretation, Computer-assisted, Reproducibility of results, Sensitivity and specificity, Transducers, Ultrasonography, Interventional

Kaynak

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

53

Sayı

2

Künye

Değertekin, F. L., Güldiken, R. O. & Karaman, M. (2006). Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 53(2), 474-482. doi:10.1109/TUFFC.2006.1593387