7 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 7 / 7
Yayın An efficient ECG data compression technique based on predefined signature and envelope vector banks(IEEE, 2005) Gürkan, Hakan; Güz, Ümit; Yarman, Bekir Sıddık BinboğaIn this paper, a new method to compress ElectroCardioGram (ECG) Signal by means of "Predefined Signature and Envelope Vector Banks-PSEVB" is presented. In this work, on a frame basis, any ECG signal is modeled by multiplying three parameters as called the Predefined Signature Vector, Predefined Envelope Vector, and Frame-Scaling Coefficient. It has been demonstrated that the predefined signature vectors and predefined envelope vectors constitute a "PSEVB" to describe any measured ECG signal. In this case, ECG signal for each frame is described in terms of the two indices "R" and "K" of PSEVB and the frame-scaling coefficient. The new compression method achieve good compression ratios with low level reconstruction error while preserving diagnostic information in the reconstructed ECG signal. Furthermore, once PSEVB are stored on each communication node, transmission of ECG signals reduces to the transmission of indexes "R" and "K" of PSEVB and the frame-scaling coefficient which also result in considerable saving in the transmission band.Yayın A novel method to represent ECG signals via predefined personalized signature and envelope functions(IEEE, 2001) Yarman, Bekir Sıddık Binboğa; Gürkan, Hakan; Güz, Ümit; Aygün, B.In this paper, a new method to model ECG signals by means of "Predefined Personalized Signature and Envelope Functions" is presented. ECG signals are somewhat unique to a person. Moreover, it presents quasi-stationary behavior. Therefore in this work, on a frame basis, personal ECG signals X-i(t) is modeled by the form of X-i(t) approximate to C(i)phi(i)(t) alpha(i)(t). In this model, phi(i)(t) is defined as the Personalized Signature Function (PSF); alpha(i)(t) is referred to as Personalized Envelope Function (PEF) and C-i is called the Frame-Scaling Coefficient (FSC). It has been demonstrated that for each person, the sets Phi = {phi(k)(t)} and A = {alpha(r)(t)} constitute a "Predefined Personalized Functional Bases or Banks (PPFB)" to describe any measured ECG signal. Almost optimum forms of (PPFB), namely {alpha(r)(t)}, {phi(k)(t)} pairs are generated in the Least Mean Square (LMS) sense. Thus, ECG signal for each frame is described in terms of the two indices "R" and "K" of PPFB and the frame-scaling coefficient Ci. It has been shown that the new method of modeling provides significant data compression. Furthermore, once PPFB are stored on each communication node, transmission of ECG signals reduces to the transmission of indexes "R" and "K" of pairs and the coefficients C-i, which also result in considerable saving in the transmission band.Yayın Elektroensefalogram (EEG) işaretlerinin sıkıştırılmasında özgün bir yaklaşım(IEEE, 2008) Gürkan, Hakan; Güz, Ümit; Yarman, Bekir Sıddık BinboğaBu çalışmada, Elektroensefalogram(EEG) işaretlerinin yeniden oluşturulmasına yönelik olarak yeni bir yöntem sunulmaktadır. Sunulan yöntem, etkin bir k-ortalamalı sınıflandırma algoritması kullanılarak Sınıflandırılmış Temel Tanım ve Zarf Vektör Setlerinin oluşturulmasına dayanmaktadır. Bu çalışmada, EEG işaretleri eşit uzunluklu çerçevelere bölünerek analiz edilmiş ve herbir çerçeve Sınıflandırılmış Temel Tanım vektörü, Sınıflandırılmış Zarf vektörü ve Çerçeve Ölçekleme Katsayısı olarak adlandırılan üç parametrenin çarpımı biçiminde modellenmiştir. Bu durumda, EEG işaretinin herbir çerçevesi sınıflandırılmış temel tanım ve zarf vektör setlerine ilişkin iki sıra numarası R ve K ile çerçeve ölçekleme katsayısı cinsinden tanımlanabilir. Önerilen yöntemin başarımı ortalama karesel hata tanımı ve görsel inceleme ölçütü yoluyla değerlendirilmiştir. Önerilen yöntem, EEG işaretlerinin tanı açısından önemli kısımları korunarak, düşük yeniden oluşturma hataları ve yüksek sıkıştırma oranları ile yeniden oluşturulmasını sağlamaktadır.Yayın A novel method to represent the speech signals by using language and speaker independent predefined functions sets(IEEE, 2004) Güz, Ümit; Gürkan, Hakan; Yarman, Bekir Sıddık BinboğaIn this paper a new modeling method of speech signals is introduced. The proposed method is based on the generation of the so-called Predefined Signature S={s(R)(t)} and Envelope Function E = {e(K)(t)} Sets (PSEFS). These function sets are independent of any speaker and any language. Once the speech signals are divided into frames with selected lengths, then each frame signal piece X-i(t) is synthesized by means of the mathematical form of x(i)(t)=C(i)e(K)(t)s(R)(t). In this representation, C-i is called the frame coefficient, s(R)(t) and e(K)(t) are properly assigned from the PSEFS respectively. It is shown that the proposed method provides fast reconstruction and substantial compression with acceptable hearing quality.Yayın A novel representation method for electromyogram (EMG) signal with predefined signature and envelope functional bank(IEEE, 2004) Gürkan, Hakan; Güz, Ümit; Yarman, Bekir Sıddık BinboğaIn this paper, a new method to model EMG signals by means of "Predefined Signature and Envelope Functional Banks (PSEB)" is presented. Since EMG signals present quasi-stationary behavior, any EMG signal Xi is modeled by the form of Xi ? Ci?K?R on a frame bases in this work. In this model, ?R is defined as the Predefined Signature Vector (PSV); ?K is referred to as Predefined Envelope Vector (PEV) and Ci is called the Frame-Scaling Coefficient (FSC). EMG signal for each frame is described in terms of the two indices "R" and "K" of PSEB and the frame -scaling coefficient Ci. Furthermore, It has been shown that the new method of modeling provides significant data compression while preserving the clinical information in the reconstructed signal.Yayın A novel method to represent speech signals(Elsevier Science BV, 2005-01) Akdeniz, Rafet; Yarman, Bekir Sıddık BinboğaIn this work, speech signals are modeled by means of the so-called pre-defined "signature functions". The pre-defined signature functions are generated using the statistical properties of the speech signals. It has been exhibited that, with a few basic signature functions, any speech signal can be generated within a tolerable error.Yayın Richards uzayında band geçiren devre fonksiyonu gerçeklemesi ve yama anten uyumlaştırmada kullanımı(IEEE, 2014-04-23) Köprü, Ramazan; Aydın, Çağatay; Yarman, Bekir Sıddık BinboğaLiteratürde çok iyi bilinmektedir ki, Richards-düzlemi, Laplace-düzleminde tanjant hiperbolik eşlemesi uygulanarak elde edilen dönüştürülmüş bir uzaydır. Richards frekansı cinsinden üretilen devre fonksiyonları gerçek frekans ekseninde π periyoduna sahiptir. Richards uzayında alçak geçiren prototip devre fonksiyonu tasarlandığında, bu periyodik özellik nedeniyle, karşı gelen periyodik band geçiren devre fonksiyonu frekans ekseninde belirli bandlarda tekrarlanarak ortaya çıkmaktadır. Tasarımcı, uygulamanın gereksinimlerine göre bu tekrarlanan bandlar arasından ilgilendiği bandı seçebilir. Bu çalışmada, 3.2448-3.744 GHz bandında çalıştırılmak üzere tasarlanmış UWB uygulamaları için elverişli bir mikroşerit yama anten için eş-uzunluklu (commensurate) iletim hatları ile oluşturulmuş uyumlaştırma devresi tasarımı ele alınmaktadır. Tasarımda, SRFT (Simplified Real Frequency Technique: Basitleştirilmiş Gerçel Frekans Tekniği) kullanılmaktadır ve teorik tasarım ile MWO (AWR) benzeşimleri arasında çok iyi uyum olduğu gözlenmiştir.












