15 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 10 / 15
Yayın Status of the Focal Plane Instrumentation (FPI) Project of the 4 m DAG Telescope(SPIE, 2016-08-09) Keskin, Onur; Yerli, Sinan Kaan; Yeşilyaprak, Cahit; Güver, Tolga; Aliş, Sinan; Yelkenci, Filiz Korhan; Güçsav, Bülent Burak; Arabacı, Mehtap Özbey; Erol, AyşeDAG (Eastern Anatolia Observatory in Turkish) will be the newest and largest (4m) observatory of Turkey in both optical (VIS) and near-infrared (NIR) Owith its robust observing site infrastructure. The telescope is designedOto house 2 Nasmyth platformes which will be dedicated to NIR and VIS observations. A collaboration has recently been established among four Turkish universities including FMV Isik University (for adaptive optics systems), Middle East Technical University (fort measurement, test and calibration purposes), Istanbul University (for new technology instruments, e.g. MKIDs) and as the coordinator Ataturk University (for obtaining NIR and VIS instruments). In this paper the status of the recently approved FPI project and its aims are presented and possible collaboration opportunities are emphasized.Yayın Evaluation of CMUT annular arrays for side-looking IVUS(IEEE, 2009) Şişman, Alper; Zahorian, Jaime S.; Gürün, Gökçe; Karaman, Mustafa; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Hasler, Paul E.Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single rotating piezoelectric transducer have simple front-end, but have fixed focused operation, and suffers from motion artifacts. Solid-state SL-IVUS imaging probes use piezoelectric transducer arrays and electronic beam-forming. Synthetic phased array processing of signals detected with small-sized elements in these arrays limits the SNR achievable with these probes. In this study, we explore a new SL-IVUS probe architecture employing rotating phased annular CMUT arrays. We tested and compared imaging performance of the existing and proposed probe configurations through simulated point spread functions. We also two fabricated sample annular array designs operating at 20-MHz and 50-MHz. Our experimental measurements on the 20-MHz array in oil shows 105% fractional bandwidth. The 50-MHz array with parylene coating shows approximately 40% fractional bandwidth measured in water. We also present imaging results acquired from wire-targets to test the experimental point-spread functions.Yayın Damariçi yanal kesit görüntüleme için farklı prob yapılarının incelenmesi(IEEE, 2009-06-26) Şişman, Alper; Karaman, MustafaBu çalışmada dönen bir şaftın yanal yüzeyine yerleştirilmiş 8 adet içiçe halka elemanlardan oluşan yana bakan görüntüleme için yeni bir kateter yapısı incelenmiştir. Bu Katater mimarisi basit bir dizi önü alıcı verici elektroniği ile değişken odaklama olanağı sağlamaktadır. Önerilen mimari, mevcut iki farklı kateter mimarisiyle benzetim sonuçları ile karşılaştırmalı olarak incelenmiştir. Benzetimlerde görüntüleme kateter çapı 1mm alınmış, farklı derinlikler ve açılar için 3 noktasal yansıtıcı ile NDF çıkarılmıştır.Yayın Design of the near infrared camera DIRAC for East Anatolia Observatory(SPIE, 2022) Zhelem, Ross; Content, Robert; Churilov, Vladimir; Kripak, Yevgen; Waller, Lew; Case, Scott; Mali, Slavko; Muller, Rolf; Gonzalez, Mario; Adams, Dave; Binos, Nick; Chin, Timothy; Farrell, Tony; Klauser, Urs; Kondrat, Yuriy; Kunwar, Nirmala; Lawrence, Jon; Lorente, Nuria; Luo, Summer; McDonald, Erica; McGregor, Helen; Nichani, Vijay; Pai, Naveen; Vuong, Minh; Zahoor, Jahanzeb; Zheng, Jessica; Norris, Barnaby; Bryant, Julia; Vaccarella, Annino; Herrald, Nick; Gilbert, James; Yeşilyaprak, Cahit; Güçsav, Bülent; Coker, Deniz; Keskin, Onur; Jolissaint, LaurentThe 4m DAG telescope is under construction at East Anatolia Observatory in Turkey. DIRAC, the " DAG InfraRed Adaptive optics Camera", is one of the facility instruments. This paper describes the design of the camera to meet the performance specifications. Adaptive and auxiliary optics relay the telescope F/14 input 1:1 into DIRAC. The camera has an all refractive design for the wavelength range 0.9 - 2.4 micron. Lenses reimage the telescope focal plane 33 x 33 as (9 x 9 mm) on a 1k x 1k focal plane array. With magnification of 2x, the plate scale on the detector is 33 mas/pixel. There are 4 standard filters (Y, J, H, K) and 4 narrowband continuum filters. A 12 position filter wheel allows installation of 2 extra customer filters for specific needs; the filter wheel also deploys a pupil viewer lens. Optical tolerancing is carried out to deliver the required image quality at polychromatic Strehl ratio of 90% with focus compensator. This reveals some challenges in the precision assembly of optics for cryogenic environments. We require cells capable of maintaining precision alignment and keeping lenses stress free. The goal is achieved by a combination of flexures with special bonding epoxy matching closely the CTE of the lens cells and crystalline materials. The camera design is very compact with object to image distance <220 mm and lens diameters <25 mm. A standalone cryostat is LN2 cooled for vibration free operation with the bench mounted adaptive optics module (TROIA) and coronagraph (PLACID) at the Nasmyth focus of the DAG telescope.Yayın Subarray delta-sigma beamforming for ultrasonic imaging(IEEE, 2002) Bilge, Hasan Şakir; Karaman, MustafaWe present a beamforming architecture based on subarray processing with non-uniform oversampling 1-bit delta-sigma (??) modulation. The subarray processing combines conventional phased array and synthetic aperture approaches to form a large aperture using small subarrays thus reduces active channel count. ??-based beamforming improves the efficiency of front-end processing further: oversampling permits precise delaying and single bit data processing simplifies beamforming operation. To reduce the number of firings we use a low beam density associated with the subarray size, and then increase the beam density by lateral interpolation prior to coherent beam summation. Our experimental test results show that the proposed scheme provides high-resolution beamforming while simplifying the front-end.Yayın Annular CMUT arrays for side looking intravascular ultrasound imaging(IEEE, 2007) Zahorian, Jaime; Güldiken, Rasim Oytun; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Carlier, Stephane; Şişman, Alper; Karaman, MustafaAlthough side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements in transducer performance are needed to perform harmonic imaging and high resolution imaging of vulnerable plaque. With their small channel count; annular arrays exploiting the inherent broad bandwidth of CMUTs and electronic focusing capability of integrated electronics provide a path for desired SL-IVUS imaging catheters. In this paper, we first describe the design, low temperature fabrication of an 8401 mu m diameter, 8 element CMUT annular array. Testing of the individual elements in oil shows a uniform device behavior with 100% fractional bandwidth around 20MHz without including the effects of attenuation and diffraction. We also present linear scan imaging results obtained on wire targets in oil, tissue and tissue mimicking phantoms using both unfocused and dynamically focused transducers. The results for axial and lateral resolution are in agreement predicted by the simulations and show the feasibility of this approach for high resolution SL-IVUS imaging.Yayın Project management of DAG: Eastern Anatolia Observatory(SPIE, 2016) Keskin, Onur; Yeşilyaprak, Cahit; Yerli, Sinan Kaan; Zago, Lorenzo; Güver, Tolga; Aliş, SinanThe four meter DAG (Eastern Anatolia Observatory in Turkish) telescope is not only the largest telescope in Turkey but also the most promising telescope in the northern hemisphere with a large potential to offer scientific observations with its cutting edge technology. DAG is designed to be an AO telescope which will allow both infrared and visible observations with its two Nasmyth platforms dedicated to next generation focal plane instruments. In this paper, status updates from DAG telescope will be presented in terms of; (i) in house optical design of DAG, (ii) tender process of telescope, (iii) tender process of enclosure, and (iv) tender process of the observatory building. Also status updates from the focal plane instruments project and possible collaboration activities will be presented.Yayın Uyarlanır yerel bağlı katman kullanan dikkat tabanlı derin ağ ile sesli komut tanıma(Institute of Electrical and Electronics Engineers Inc., 2020-10-05) Turkan, Yasemin; Tek, Faik BoraySesli komut tanıma insan-makine ara yüzüyle ilişkili aktif bir araştırma konusudur. Dikkat tabanlı derin ağlar ile bu tür problemler başarılı bir şekilde çözülebilmektedir. Bu çalışmada, var olan bir dikkat tabanlı derin ağ yöntemi, uyarlanır yerel bağlı (odaklanan) katman kullanılarak daha da geliştirilmiştir. Orijinal yönteminde sınandığı Google ve Kaggle sesli komut veri setlerinde karşılaştırmalı olarak yapılan deneylerde önerdiğimiz uyarlanır yerel bağlı katman kullanan dikkat tabanlı ağın tanıma doğruluğunu %2.6 oranında iyileştirdiği gözlemledik.Yayın Eastern Anatolia Observatory (DAG): Recent developments 2017(SPIE-INT Soc Optical Engineering, 2018-07-06) Yeşilyaprak, Cahit; Keskin, OnurEast Anatolia Observatory (DAG) is the new observatory of Turkey with the optical (VIS) and near-infrared (NIR) largest telescope (4 m mirror) and its robust observing site infrastructure. This national project consists of three phases with DAG (telescope, enclosure, building, infrastructure), FPI (Focal Plane Instruments and Adaptive Optics) and MCP (Mirror Coating Plant) and is supported by the Ministry of Development of Turkey. Almost all infrastructure (roads, geological and atmospheric surveys, electricity, fiber optics, water, generator, etc.) of DAG site (Erzurum/Turkey, 3170 m altitude) have been completed. The recent developments (telescope, enclosure, mirror, focal plane instruments, building, atmospheric studies, etc.) of DAG and its site in 2017 and 2018 were presented for the future possible collaborations for various astronomical instruments and telescopes which can be set up in DAG site.Yayın An adaptive locally connected neuron model: Focusing neuron(Elsevier B.V., 2021-01-02) Tek, Faik BorayThis paper presents a new artificial neuron model capable of learning its receptive field in the topological domain of inputs. The experiments include tests of focusing neuron networks of one or two hidden layers on synthetic and well-known image recognition data sets. The results demonstrated that the focusing neurons can move their receptive fields towards more informative inputs. In the simple two-hidden layer networks, the focusing layers outperformed the dense layers in the classification of the 2D spatial data sets. Moreover, the focusing networks performed better than the dense networks even when 70% of the weights were pruned. The tests on convolutional networks revealed that using focusing layers instead of dense layers for the classification of convolutional features may work better in some data sets.












