Arama Sonuçları

Listeleniyor 1 - 10 / 11
  • Yayın
    Evaluation of CMUT annular arrays for side-looking IVUS
    (IEEE, 2009) Şişman, Alper; Zahorian, Jaime S.; Gürün, Gökçe; Karaman, Mustafa; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Hasler, Paul E.
    Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single rotating piezoelectric transducer have simple front-end, but have fixed focused operation, and suffers from motion artifacts. Solid-state SL-IVUS imaging probes use piezoelectric transducer arrays and electronic beam-forming. Synthetic phased array processing of signals detected with small-sized elements in these arrays limits the SNR achievable with these probes. In this study, we explore a new SL-IVUS probe architecture employing rotating phased annular CMUT arrays. We tested and compared imaging performance of the existing and proposed probe configurations through simulated point spread functions. We also two fabricated sample annular array designs operating at 20-MHz and 50-MHz. Our experimental measurements on the 20-MHz array in oil shows 105% fractional bandwidth. The 50-MHz array with parylene coating shows approximately 40% fractional bandwidth measured in water. We also present imaging results acquired from wire-targets to test the experimental point-spread functions.
  • Yayın
    Dual-annular-ring CMUT array for forward-looking IVUS imaging
    (IEEE, 2006) Güldiken, Rasim Oytun; Zahorian, Jaime; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Tekeş, Coşkun; Şişman, Alper; Karaman, Mustafa
    We investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same silicon substrate. This configuration has the potential for independent optimization of each array and uses the silicon area more effectively without any particular drawback. We designed and fabricated a 1mm diameter test array which consists of 24 transmit and 32 receive elements. We investigated synthetic phased array beamforming with a non-redundant subset (if transmit-receive element pairs of the dual-annular-ring array. For imaging experiments, we designed and constructed a programmable FPGA-based data acquisition and phased array beamforming system. Pulse-echo measurements along with imaging simulations suggest that dual-ring-annular array should provide performance suitable for real-time FLAVUS applications.
  • Yayın
    Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results
    (IEEE, 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Tekeş, Coşkun; Hasler, Paul E.; Karaman, Mustafa; Carlier, Stephane; Değertekin, Fahrettin Levent
    This paper presents the experimental results on forward-looking Intravascular ultrasound (FL-IVUS) using dual-annular-ring CMUT arrays. The array has a diameter of 1mm including bondpads which consists of separate, concentric 24 transmit and 32 receive ring arrays built on the same silicon substrate. This configuration has the potential for Independent optimization of each array and uses the silicon area more effectively without any drawback. For imaging experiments, we designed and constructed a custom integrated circuit using a standard 0.5 mu m CMOS process for data acquisition. A sample pulse-echo signal received from the oil-air Interface (plane reflector) at 6mm had a center frequency of 11MHz with 95% fractional 6-dB bandwidth. The measured SNR of the echo was 24 dB with no averaging. B-scan image of a wire-phantom was generated to test the resolution.
  • Yayın
    Annular CMUT arrays for side looking intravascular ultrasound imaging
    (IEEE, 2007) Zahorian, Jaime; Güldiken, Rasim Oytun; Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Carlier, Stephane; Şişman, Alper; Karaman, Mustafa
    Although side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements in transducer performance are needed to perform harmonic imaging and high resolution imaging of vulnerable plaque. With their small channel count; annular arrays exploiting the inherent broad bandwidth of CMUTs and electronic focusing capability of integrated electronics provide a path for desired SL-IVUS imaging catheters. In this paper, we first describe the design, low temperature fabrication of an 8401 mu m diameter, 8 element CMUT annular array. Testing of the individual elements in oil shows a uniform device behavior with 100% fractional bandwidth around 20MHz without including the effects of attenuation and diffraction. We also present linear scan imaging results obtained on wire targets in oil, tissue and tissue mimicking phantoms using both unfocused and dynamically focused transducers. The results for axial and lateral resolution are in agreement predicted by the simulations and show the feasibility of this approach for high resolution SL-IVUS imaging.
  • Yayın
    Forward-looking IVUS imaging using an annular-ring CMUT array
    (IEEE, 2005) Değertekin, Fahrettin Levent; Karaman, Mustafa; Güldiken, Rasim Oytun
    A 64-element, 1.15mm diameter annular-ring CMUT array was characterized and used for forward-looking IVUS imaging tests. The array was manufactured using low temperature processes suitable for CMOS electronics integration on a single chip. The 43×140µm2 array element has suitable view angle for forward looking imaging around 15MHz center frequency and pulse-echo measurements show nearly 100% fractional bandwidth around 17MHz. For imaging and SNR measurements, RF A-scan data sets from various targets were collected using an interconnect scheme forming a 32-element array configuration. The results demonstrate that annular-ring CMUT arrays fabricated with CMOS compatible processes are capable of forward-looking IVUS imaging.
  • Yayın
    Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results
    (2008) Gürün, Gökçe; Qureshi, Muhammad Shakeel; Balantekin, Müjdat; Güldiken, Rasim Oytun; Zahorian, Jaime S.; Peng, Shengyu; Basu, Arindam; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin Levent
    This paper discusses design of CMOS-ASICs for monolithic integration of CMUT arrays by post-CMOS fabrication. We describe design strategies for monolithic integration and demonstrate the advantages of CMUT-on-CMOS approach. On the same wafer, separate sets of IC cells are designed to interface different types of CMUT arrays for IVUS and ICE applications. Circuit topologies include resistive feedback transimpedance amplifiers on the receiver side, along with multiplexers and buffers. Gains and bandwidths of receiving amplifiers are optimized separately to fit different array specifications such as number of elements, element size and operation bandwidth. To drive CMUTs a high voltage pulser array is designed in the same 3.3V unmodified CMOS technology by combining existing technological layers in an unconventional way. CMUT arrays are then built on top of the custom made 8" wafer containing these circuits fabricated in a 0.35µm standard CMOS process. We present initial characterization of the CMO electronics and pulse-echo measurements obtained post-CMOS fabricated CMUT elements.
  • Yayın
    Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging
    (IEEE, 2006-02) Değertekin, Fahrettin Levent; Güldiken, Rasim Oytun; Karaman, Mustafa
    In this study, a 64-element, 1.15-mm diameter annular-ring capacitive micromachined ultrasonic transducer (CMUT) array was characterized and used for forward-looking intravascular ultrasound (IVUS) imaging tests. The array was manufactured using low-temperature processes suitable for CMOS electronics integration oil a single chip. The measured radiation pattern of a 43 X 140- mu m(2) array element depicts a 40 degrees view angle for forward-looking imaging around a 15-MHz center frequency in agreement with theoretical models. Pulse-echo measurements show a -10-dB fractional bandwidth of 104% around 17 MHz for wire targets 2.5 mm away from the array in vegetable oil. For imaging and SNR measurements, RF A-scan data sets from various targets were collected using all interconnect scheme forming a 32-element array configuration. An experimental point spread function was obtained and compared with simulated and theoretical array responses, showing good agreement. Therefore, this study demonstrates that annular-ring CMUT arrays fabricated with CMOS-compatible processes are capable of forward-looking IVUS imaging, and the developed modeling tools can be used to design improved IVUS imaging arrays.
  • Yayın
    Dual electrode capacitive micromachined ultrasonic transducer array for 1-D intracardiac echocardiography (ICE)
    (American Society of Mechanical Engineers (ASME), 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Karaman, Mustafa; Değertekin, Fahrettin Levent
    We designed and fabricated a 64 element 1-D linear dual electrode Capacitive Micromachined Ultrasonic Transducer (CMUT) array operating at 9.5 MHz for Intracardiac Echocardiography (ICE). The dual electrode CMUT structure increases the overall sensitivity by 12.6dB (6.2dB in receive sensitivity; 6.4dB in output pressure) when compared to optimized single electrode CMUT. We report peak output pressure of 2.3MPa on the CMUT surface when 170V AC and 180V DC is applied. This significant performance increase makes the CMUT more competitive with their piezoelectric counterparts.
  • Yayın
    Micromachined capacitive transducer arrays for intravascular ultrasound
    (SPIE, 2005) Değertekin, Fahrettin Levent; Güldiken, Rasim Oytun; Karaman, Mustafa
    Intravascular ultrasound (IVUS) imaging has become an essential imaging modality for the effective diagnosis and treatment of cardiovascular diseases during the past decade enabled by innovative applications of piezoelectric transducer technology. The limitations in the manufacture and performance of the same piezoelectric transducers have also impeded the improvement of IVUS for emerging clinically important applications such as forward viewing arrays for guiding interventions and high resolution imaging of arterial structure such as vulnerable plaque and fibrous cap, and also implementation of techniques such as harmonic imaging of the tissue and of the contrast agents. Capacitive micromachined ultrasonic transducer (CMUT) technology shows great potential for transforming IVUS not only to satisfy these clinical needs but also to open up possibilities for low-cost imaging devices integrated to therapeutic tools. We have developed manufacturing processes with a maximum process temperature of 250°C to build CMUTs on the same silicon chip with integrated electronics. Using these processes we fabricated CMUT arrays suitable for forward viewing IVUS in the 10-20MHz range. We characterized these array elements in terms of pulse-echo response, radiation pattern measurements and demonstrated its volumetric imaging capabilities on various imaging targets.
  • Yayın
    Multiple annular ring capacitive micromachined ultrasonic transducer arrays for forward-looking intravascular ultrasound imaging catheters
    (American Society of Mechanical Engineers (ASME), 2007) Güldiken, Rasim Oytun; Zahorian, Jaime S.; Balantekin, Müjdat; Karaman, Mustafa; Değertekin, Fahrettin Levent
    We investigate multiple-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. This configuration has the potential for independent optimization of each ring and uses the silicon area more effectively without any particular drawback. We designed and fabricated a sample 1mm diameter dual annular ring CMUT test array which consists of 24 transmit and 32 receive elements. For imaging experiments, we designed IC chips that contain 8 transimpedance amplifiers, a multiplexer and a buffer. The real time-pulse echo experiments obtained with designed IC electronics show 26dB Signal to Noise Ratio (SNR) from a 3.5 mm away aluminum reflector in oil. This paper presents our first efforts in obtaining real time imaging with designed IC chips which is one step before CMUT on CMOS implementation.