4 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 4 / 4
Yayın Phased subarray imaging for low-cost, wideband coherent array imaging(IEEE, 2003) Johnson, Jeremy A.; Oralkan, Ömer; Ergün, Arif Sanlı; Demirci, Utkan; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasThe front-end hardware complexity of conventional full phased array (FPA) imaging is proportional to the number of array elements. Phased subarray (PSA) imaging has been proposed as a method of reducing the hardware complexity-and therefore system cost and size-while achieving near-FPA image quality. A new method is presented for designing the subarray-dependent interpolation filters suitable for wideband PSA imaging. The method was tested experimentally using pulse-echo data of a wire target phantom acquired using a 3.2-cm. 128-element capacitive micromachined ultrasonic transducer (CMUT) array with 85% fractional bandwidth at 3 MHz. A specific PSA configuration using seven 32-element subarrays was compared to FPA imaging, representing a 4-fold reduction in front-end hardware complexity and a 43% decrease in frame rate. For targets near the fixed transmit focal distance, the mean 6-dB lateral resolution was identical to that of FPA, the axial resolution improved by 4%, and the SNR decreased by 5 dB. Measurements were repeated for 10 different PSA configurations with subarray sizes ranging from 4 to 60. The lateral and axial resolutions did not vary significantly with subarray size; both the SNR and contrast-to-noise ratio (CNR) improved with increased subarray size.Yayın An integrated circuit with transmit beamforming and parallel receive channels for 3D ultrasound imaging: testing and characterization(IEEE, 2007) Wygant, Ira O.; Jamal, Nafis S.; Lee, Hyunjoo J.; Nikoozadeh, Amin; Zhuang, Xuefeng; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasThe cost and complexity of medical ultrasound imaging systems can be reduced by integrating the transducer array with an integrated circuit (IC). By incorporating some of the system's front-end electronics into an IC, bulky cables and costly system electronics can be eliminated. Here we present an IC for 3D intracavital imaging that requires few electrical connections but uses a large fraction of a 16x16-element 2D transducer array to transmit focused ultrasound. To simplify the receive and data acquisition electronics, only the 32 elements along the array diagonals are used as receivers. The IC provides a preamplifier for each receiving element. Each of the 224 transmitting elements is provided an 8-bit shift register, a comparator, and a 25-V pulser. To transmit, a global counter is incremented from 1 to 224; each pulser fires when its stored register value is equal to the global count value. Electrical testing of the fabricated IC shows that it works as designed. The IC was flip-chip bonded to a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array. A two-dimensional image of a wire target phantom was acquired.Yayın Beamforming and hardware design for a multichannel front-end integrated circuit for real-time 3D catheter-based ultrasonic imaging(SPIE-Int Soc Optical Engineering, 2006) Wygant, Ira O.; Karaman, Mustafa; Oralkan, Ömer; Khuri-Yakub, Butrus ThomasWe are working on integrating front-end electronics with the ultrasound transducer array for real-time 3D ultrasound imaging systems. We achieve this integration by flip-chip bonding a two-dimensional transducer array to an integrated circuit (IC) that comprises the front-end electronics. The front-end IC includes preamplifiers, multiplexers, and pulsers. We recently demonstrated a catheter-based real-time ultrasound imaging system based on a 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array. The CMUT array is flip-chip bonded to a front-end IC that includes a pulser and preamplifier for each element of the array. To simplify the back-end processing and signal routing on the IC for this initial implementation, only a single array element is active at a time (classic synthetic aperture (CSA) imaging). Compared with classic phased array imaging (CPA), where multiple elements are used on transmit and receive, CSA imaging has reduced signal-to-noise ratio and prominent grating lobes. In this work, we evaluate three array designs for the next generation front-end IC. The designs assume there are 16 receive channels and that numerous transmit pulsers are provided by the IC. The designs presented are: plus-transmit x-receive, boundary-transmit x-receive with no common elements, and full-transmit x-receive with no common elements. Each design is compared with CSA and CPA imaging. We choose to implement an IC for the full-transmit x-receive with no common elements (FT-XR-NC) design for our next-generation catheter-based imaging system.Yayın Minimally redundant 2-D array designs for 3-D medical ultrasound imaging(IEEE-Inst Electrical Electronics Engineers Inc, 2009-07) Karaman, Mustafa; Wygant, Ira O.; Oralkan, Ömer; Khuri-Yakub, Butrus ThomasIn real-time ultrasonic 3-D imaging, in addition to difficulties in fabricating and interconnecting 2-D transducer arrays with hundreds of elements, there are also challenges in acquiring and processing data from a large number of ultrasound channels. The coarray (spatial convolution of the transmit and receive arrays) can be used to find efficient array designs that capture all of the spatial frequency content (a transmit-receive element combination corresponds to a spatial frequency) with a reduced number of active channels and firing events. Eliminating the redundancies in the transmit-receive element combinations and firing events reduces the overall system complexity and improves the frame rate. Here we explore four reduced redundancy 2-D array configurations for miniature 3-D ultrasonic imaging systems. Our approach is based on 1) coarray design with reduced redundancy using different subsets of linear arrays constituting the 2-D transducer array, and 2) 3-D scanning using fan-beams (narrow in one dimension and broad in the other dimension) generated by the transmit linear arrays. We form the overall array response through coherent summation of the individual responses of each transmit-receive array pairs. We present theoretical and simulated point spread functions of the array configurations along with quantitative comparison in terms of the front-end complexity and image quality.












