Arama Sonuçları

Listeleniyor 1 - 10 / 32
  • Yayın
    Phased subarray imaging for low-cost, wideband coherent array imaging
    (IEEE, 2003) Johnson, Jeremy A.; Oralkan, Ömer; Ergün, Arif Sanlı; Demirci, Utkan; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas
    The front-end hardware complexity of conventional full phased array (FPA) imaging is proportional to the number of array elements. Phased subarray (PSA) imaging has been proposed as a method of reducing the hardware complexity-and therefore system cost and size-while achieving near-FPA image quality. A new method is presented for designing the subarray-dependent interpolation filters suitable for wideband PSA imaging. The method was tested experimentally using pulse-echo data of a wire target phantom acquired using a 3.2-cm. 128-element capacitive micromachined ultrasonic transducer (CMUT) array with 85% fractional bandwidth at 3 MHz. A specific PSA configuration using seven 32-element subarrays was compared to FPA imaging, representing a 4-fold reduction in front-end hardware complexity and a 43% decrease in frame rate. For targets near the fixed transmit focal distance, the mean 6-dB lateral resolution was identical to that of FPA, the axial resolution improved by 4%, and the SNR decreased by 5 dB. Measurements were repeated for 10 different PSA configurations with subarray sizes ranging from 4 to 60. The lateral and axial resolutions did not vary significantly with subarray size; both the SNR and contrast-to-noise ratio (CNR) improved with increased subarray size.
  • Yayın
    Integrated ultrasonic imaging systems based on CMUT arrays: Recent progress
    (IEEE, 2004) Wygant, Ira O.; Zhuang, Xuefeng; Yeh, David T.; Nikoozadeh, Amin; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas
    This paper describes the development of an ultrasonic imaging system based on a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array. The transducer array and front-end electronics are designed to fit in a 5-mm endoscopic channel. A custom-designed integrated circuit, which comprises the front-end electronics, will be connected with the transducer elements via through-wafer interconnects and flip-chip bonding. FPGA-based signal-processing hardware will provide real-time three-dimensional imaging. The imaging system is being developed to demonstrate a means of integrating the front-end electronics with the transducer array and to provide a clinically useful technology. Integration of the electronics can improve signal-to-noise ratio, reduce the number of cables connecting the imaging probe to a separate processing unit, and provide a means of connecting electronics to large two-dimensional transducer arrays. This paper describes the imaging system architecture and the progress we have made on implementing each of its components: a 16×16 CMUT array, custom-designed integrated circuits, a flip-chip bonding technique, and signal-processing hardware.
  • Yayın
    Co-array optimization of CMUT arrays for forward-looking IVUS
    (IEEE, 2009-09) Tekeş, Coşkun; Karaman, Mustafa; Değertekin, Fahrettin Levent
    The ring annular array structure is a preferred configuration for implementing Forward-Looking IVUS (FLIVUS) catheters as it allows for volumetric imaging as well as use of a guidewire at the center. CMUT technology is promising for these arrays especially with the flexibility of locating array elements on the circular donut area efficiently. To take advantage of this flexibility, in this study, we introduce a new co-array sampling strategy that improves imaging performance while keeping the number of firings at a level suitable for real-time imaging. The presented co-array sampling strategy is based on the idea of adjusting the element density of the co-array rings in radial direction to suppress side lobes. In non-uniform sampling of the co-array with a given number of firings, the inter-element distances are adjusted both in radial and angular direction from inner ring to outer ring to fit a given apodization function. To test the imaging performance, we performed numerical simulations of the co-array with non-uniform sampling fitting to the raised-cosine apodization. The simulation results shows that sidelobe level can be reduced more than 10 dB by using non-uniform co-array sampling. This approach does use uniform weighting of all Tx and Rx elements in beamforming, and hence does not cause any SNR loss for apodization.
  • Yayın
    Volumetric ultrasound imaging using 2-D CMUT arrays
    (IEEE-Inst Electrical Electronics Engineers Inc, 2003-11) Oralkan, Ömer; Ergün, Arif Sanlı; Cheng, Ching-Hsiang; Johnson, Jeremy A.; Karaman, Mustafa; H. Lee, Thomas; Khuri-Yakub, Butrus Thomas
    Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128 x 128-element 2-D CMUT array with through-wafer via interconnects and a 420-mum element pitch. As an experimental prototype, a 32 x 64-element portion of the 128 X 128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16 X 16-element portion of the array to surrounding bondpads. An 8 x 16-element poition of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4 X 4 group of elements in the middle of the 8 X 16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to integrate these dense 2-D arrays with electronic circuits for practical 3-D imaging applications.
  • Yayın
    Evaluation of CMUT annular arrays for side-looking IVUS
    (IEEE, 2009) Şişman, Alper; Zahorian, Jaime S.; Gürün, Gökçe; Karaman, Mustafa; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Hasler, Paul E.
    Side-looking (SL) IVUS probes are extensively used for management of cardiovascular diseases. Currently SL-IVUS imaging probes use either a single rotating transducer element or solid-state arrays. Probes with single rotating piezoelectric transducer have simple front-end, but have fixed focused operation, and suffers from motion artifacts. Solid-state SL-IVUS imaging probes use piezoelectric transducer arrays and electronic beam-forming. Synthetic phased array processing of signals detected with small-sized elements in these arrays limits the SNR achievable with these probes. In this study, we explore a new SL-IVUS probe architecture employing rotating phased annular CMUT arrays. We tested and compared imaging performance of the existing and proposed probe configurations through simulated point spread functions. We also two fabricated sample annular array designs operating at 20-MHz and 50-MHz. Our experimental measurements on the 20-MHz array in oil shows 105% fractional bandwidth. The 50-MHz array with parylene coating shows approximately 40% fractional bandwidth measured in water. We also present imaging results acquired from wire-targets to test the experimental point-spread functions.
  • Yayın
    An Analog beamformer for integrated high-frequency medical ultrasound imaging
    (IEEE, 2011) Gürün, Gökçe; Zahorian, Jaime; Tekeş, Coşkun; Karaman, Mustafa; Hasler, Paul E.; Değertekin, Fahrettin Levent
    We designed and fabricated a dynamic receive beamforming integrated circuit (IC) in 0.35-mu m CMOS technology. This beamformer is suitable for integration with an ultrasound annular array for high-frequency (30-50 MHz) intravascular ultrasound (IVUS) imaging. The beamformer IC is capable of buffering, delaying and preamplification for 8 receive channels. We explored an analog delay cell based on a currentmode first-order all-pass filter, which is used as the basic building block to form an analog dynamic delay line. We also explored a bandwidth enhancement method on the delay cell that improved the overall bandwidth of the delay line by a factor of 6. Each delay cell consumes 2.1 mW of power and is capable of generating a tunable delay between 1.75 ns to 2.5 ns, enabling dynamic receive beamforming over a focal range from 1.4 mm to 2 mm. We successfully integrated the fabricated beamformer IC with an 8-element annular array. Our experimental test results demonstrated the desired buffering, preamplification and delaying capabilities of the beamformer.
  • Yayın
    Damariçi yanal kesit görüntüleme için farklı prob yapılarının incelenmesi
    (IEEE, 2009-06-26) Şişman, Alper; Karaman, Mustafa
    Bu çalışmada dönen bir şaftın yanal yüzeyine yerleştirilmiş 8 adet içiçe halka elemanlardan oluşan yana bakan görüntüleme için yeni bir kateter yapısı incelenmiştir. Bu Katater mimarisi basit bir dizi önü alıcı verici elektroniği ile değişken odaklama olanağı sağlamaktadır. Önerilen mimari, mevcut iki farklı kateter mimarisiyle benzetim sonuçları ile karşılaştırmalı olarak incelenmiştir. Benzetimlerde görüntüleme kateter çapı 1mm alınmış, farklı derinlikler ve açılar için 3 noktasal yansıtıcı ile NDF çıkarılmıştır.
  • Yayın
    Dual-annular-ring CMUT array for forward-looking IVUS imaging
    (IEEE, 2006) Güldiken, Rasim Oytun; Zahorian, Jaime; Balantekin, Müjdat; Değertekin, Fahrettin Levent; Tekeş, Coşkun; Şişman, Alper; Karaman, Mustafa
    We investigate a dual-annular-ring CMUT array configuration for forward-looking intravascular ultrasound (FL-IVUS) imaging. The array consists of separate, concentric transmit and receive ring arrays built on the same silicon substrate. This configuration has the potential for independent optimization of each array and uses the silicon area more effectively without any particular drawback. We designed and fabricated a 1mm diameter test array which consists of 24 transmit and 32 receive elements. We investigated synthetic phased array beamforming with a non-redundant subset (if transmit-receive element pairs of the dual-annular-ring array. For imaging experiments, we designed and constructed a programmable FPGA-based data acquisition and phased array beamforming system. Pulse-echo measurements along with imaging simulations suggest that dual-ring-annular array should provide performance suitable for real-time FLAVUS applications.
  • Yayın
    Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays
    (IEEE-INST Electrical Electronics Engineers Inc, 2005-12) Çiçek, İhsan; Bozkurt, Ayhan; Karaman, Mustafa
    Integration of front-end electronics with 2D capacitive micromachined ultrasonic transducer (CMUT) arrays has been a challenging issue due to the small element size and large channel count. We present design and verification of a front-end drive-readout integrated circuit for 3D ultrasonic imaging using 2D CMUT arrays. The circuit cell dedicated to a single CMUT array element consists of a high-voltage pulser and a low-noise readout amplifier. To analyze the circuit cell together with the CMUT element, we developed an electrical CMUT model with parameters derived through finite element analysis, and performed both the pre- and postlayout verification. An experimental chip consisting of 4 x 4 array of the designed circuit cells, each cell occupying a 200 x 200 mu m(2) area, was formed for the initial test studies and scheduled for fabrication in 0.8 mu m, 50 V CMOS technology. The designed circuit is suitable for integration with CMUT arrays through flip-chip bonding and the CMUT-on-CMOS process.
  • Yayın
    An endoscopie imaging system based on a two-dimensional CMUT array: real-time imaging results
    (IEEE, 2005) Wygant, Ira O.; Zhuang, Xuefeng; Yeh, David T.; Vaithilingam, Srikant; Nikoozadeh, Amin; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus Thomas
    Real-time catheter-based ultrasound imaging tools are needed for diagnosis and image-guided procedures. The continued development of these tools is partially limited by the difficulty of fabricating two-dimensional array geometries of piezoelectric transducers. Using capacitive micromachined ultrasonic transducer (CMUT) technology, transducer arrays with widely varying geometries, high frequencies, and wide bandwidths can be fabricated. A volumetric ultrasound imaging system based on a two-dimensional, 16×l6-element, CMUT array is presented. Transducer arrays with operating frequencies ranging from 3 MHz to 7.5 MHz were fabricated for this system. The transducer array including DC bias pads measures 4 mm by 4.7 mm. The transducer elements are connected to flip-chip bond pads on the array back side with 400-?m long through-wafer interconnects. The array is flip-chip bonded to a custom-designed integrated circuit (IC) that comprises the front-end electronics. Integrating the front-end electronics with the transducer array reduces the effects of cable capacitance on the transducer's performance and provides a compact means of connecting to the transducer elements. The front-end IC provides a 27-V pulser and 10-MHz bandwidth amplifier for each element of the array. An FPGA-based data acquisition system is used for control and data acquisition. Output pressure of 230 kPa was measured for the integrated device. A receive sensitivity of 125 mV/kPa was measured at the output of the amplifier. Amplifier output noise at 5 Mhz is 112 nV/?Hz. Volumetric images of a wire phantom and vessel phantom are presented. Volumetric data for a wire phantom was acquired in real-time at 30 frames per second.