12 sonuçlar
Arama Sonuçları
Listeleniyor 1 - 10 / 12
Yayın Volumetric ultrasound imaging using 2-D CMUT arrays(IEEE-Inst Electrical Electronics Engineers Inc, 2003-11) Oralkan, Ömer; Ergün, Arif Sanlı; Cheng, Ching-Hsiang; Johnson, Jeremy A.; Karaman, Mustafa; H. Lee, Thomas; Khuri-Yakub, Butrus ThomasRecently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128 x 128-element 2-D CMUT array with through-wafer via interconnects and a 420-mum element pitch. As an experimental prototype, a 32 x 64-element portion of the 128 X 128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16 X 16-element portion of the array to surrounding bondpads. An 8 x 16-element poition of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4 X 4 group of elements in the middle of the 8 X 16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to integrate these dense 2-D arrays with electronic circuits for practical 3-D imaging applications.Yayın An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging(IEEE-INST Electrical Electronics Engineers Inc, 2009-10) Wygant, Ira O.; Jamal, Nafis S.; Lee, Hyunjoo J.; Nikoozadeh, Amin; Oralkan, Ömer; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasState-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of elements. A tight combination of the transducer array with integrated circuitry eliminates bulky cables connecting the elements of the transducer array to a separate system of electronics. Furthermore, preamplifiers located close to the array can lead to improved receive sensitivity. A combined IC and transducer array can lead to a portable, high-performance, and inexpensive 3-D ultrasound imaging system. This paper presents an IC flip-chip bonded to a 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array for 3-D ultrasound imaging. The IC includes a transmit beamformer that generates 25-V unipolar pulses with programmable focusing delays to 224 of the 256 transducer elements. One-shot circuits allow adjustment of the pulse widths for different ultrasound transducer center frequencies. For receiving reflected ultrasound signals, the IC uses the 32-elements along the array diagonals. The IC provides each receiving element with a low-noise 25-MHz-bandwidth transimpedance amplifier. Using a field-programmable gate array (FPGA) clocked at 100 MHz to operate the IC, the IC generated property timed transmit pulses with 5-ns accuracy. With the IC flip-chip bonded to a CMUT array, we show that the IC can produce steered and focused ultrasound beams. We present 2-D and 3-D images of a wire phantom and 2-D orthogonal cross-sectional images (B-scans) of a latex heart phantom.Yayın Optimizing circular ring arrays for forward-looking IVUS imaging(IEEE-Inst Electrical Electronics Engineers Inc, 2011-12) Tekeş, Coşkun; Karaman, Mustafa; Değertekin, Fahrettin LeventForward-looking (FL) catheter-based imaging systems are highly desirable for guiding interventions in intravascular ultrasound (IVUS) applications. One of the main challenges of array-based FL-IVUS systems is the large channel count, which results in increased system complexity. Synthetic phased-array processing with a reduced firing count simplifies the front-end and, hence, can enable 3-D real-time imaging. Recently, we have investigated dual-ring arrays suitable for IVUS imaging, in which the two concentric circular arrays are used separately as transmit (Tx) and receive (Rx) arrays. In this study, we present different optimized array designs based on dual and single circular rings which are suitable for synthetic phased-array processing with a reduced number of firings. To obtain an optimal firing set that produces low side lobes in the wideband response, we use a simulated annealing algorithm. In the simulations, we use 1.2-mm-diameter array configurations with 64 Tx and 58 Rx elements, a center frequency of 20 MHz and fractional bandwidths of 50% and 80%. The results show that optimized dual-ring arrays provide 8 dB improvements in peak near side-lobe level with no widening in the main lobe width when compared with full and other sparse co-arrays.Yayın Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays(IEEE-INST Electrical Electronics Engineers Inc, 2005-12) Çiçek, İhsan; Bozkurt, Ayhan; Karaman, MustafaIntegration of front-end electronics with 2D capacitive micromachined ultrasonic transducer (CMUT) arrays has been a challenging issue due to the small element size and large channel count. We present design and verification of a front-end drive-readout integrated circuit for 3D ultrasonic imaging using 2D CMUT arrays. The circuit cell dedicated to a single CMUT array element consists of a high-voltage pulser and a low-noise readout amplifier. To analyze the circuit cell together with the CMUT element, we developed an electrical CMUT model with parameters derived through finite element analysis, and performed both the pre- and postlayout verification. An experimental chip consisting of 4 x 4 array of the designed circuit cells, each cell occupying a 200 x 200 mu m(2) area, was formed for the initial test studies and scheduled for fabrication in 0.8 mu m, 50 V CMOS technology. The designed circuit is suitable for integration with CMUT arrays through flip-chip bonding and the CMUT-on-CMOS process.Yayın Forward-viewing CMUT arrays for medical Imaging(IEEE-INST Electrical Electronics Engineers Inc, 2004-07) Demirci, Utkan; Ergün, Arif Sanlı; Oralkan, Ömer; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasThis paper reports the design and testing of forward-viewing annular arrays fabricated using capacitive micromachined ultrasonic transducer (CMUT) technology. Recent research studies have shown that CMUTs have broad frequency bandwidth and high-transduction efficiency. One- and two-dimensional CMUT arrays of various sizes already have been fabricated, and their viability for medical imaging applications has been demonstrated. We fabricated 64-element, forward-viewing annular arrays using the standard CMUT fabrication process and carried out experiments to measure the operating frequency, bandwidth, and transmit/receive efficiency of the array elements. The annular array elements, designed for imaging applications in the 20 MHz range, had a resonance frequency of 13.5 MHz in air. The immersion pulse-echo data collected from a plane reflector showed that the devices operate in the 5-26 MHz range with a fractional bandwidth of 135%. The output pressure at the surface of the transducer was measured to be 24 kPa/V. These values translate into a dynamic range of 131.5 dB for I-V excitation in 1-Hz bandwidth with a commercial low noise receiving circuitry. The designed, forward-viewing annular CMUT array is suitable for mounting on the front surface of a cylindrical catheter probe and can provide Doppler information for measurement of blood flow and guiding information for navigation through blood vessels in intravascular ultrasound imaging.Yayın Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging(IEEE-INST Electrical Electronics Engineers Inc, 2008-02) Wygant, Ira O.; Zhuang, Xuefeng; Yeh, David T.; Oralkan, Ömer; Ergün, Arif Sanlı; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasFor three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging system's front-end electronics is a challenge because of the large number of array elements and the small element size. To compactly connect the transducer array with electronics, we flip-chip bond a 2D 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array to a custom-designed integrated circuit (IC). Through-wafer interconnects are used to connect the CMUT elements on the top side of the array with flip-chip bond pads on the back side. The IC provides a 25-V pulser and a transimpedance preamplifier to each element of the array. For each of three characterized devices, the element yield is excellent (99 to 100% of the elements are functional). Center frequencies range from 2.6 MHz to 5.1 MHz. For pulse-echo operation, the average -6-dB fractional bandwidth is as high as 125%. Transmit pressures normalized to the face of the transducer are as high as 339 kPa and input-referred receiver noise is typically 1.2 to 2.1 mPa/root Hz. The flip-chip bonded devices were used to acquire 3D synthetic aperture images of a wire-target phantom. Combining the transducer array and IC, as shown in this paper, allows for better utilization of large arrays, improves receive sensitivity, and may lead to new imaging techniques that depend on transducer arrays that are closely coupled to IC electronics.Yayın Monolithic CMUT-on-CMOS integration for intravascular ultrasound applications(IEEE-INST Electrical Electronics Engineers Inc, 2011-12) Zahorian, Jaime S.; Hochman, Michael; Xu, Toby; Satır, Sarp; Gürün, Gökçe; Karaman, Mustafa; Değertekin, Fahrettin LeventOne of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, especially in catheter-based volumetric imaging arrays, for which the elements must be small. Furthermore, optimization of the available silicon area and minimized number of connections occurs when the CMUTs are fabricated directly above the associated electronics. Here, we describe successful fabrication and performance evaluation of CMUT arrays for intravascular imaging on custom-designed CMOS receiver electronics from a commercial IC foundry. The CMUT-on-CMOS process starts with surface isolation and mechanical planarization of the CMOS electronics to reduce topography. The rest of the CMUT fabrication is achieved by modifying a low-temperature micromachining process through the addition of a single mask and developing a dry etching step to produce sloped sidewalls for simple and reliable CMUT-to-CMOS interconnection. This CMUT-to-CMOS interconnect method reduced the parasitic capacitance by a factor of 200 when compared with a standard wire-bonding method. Characterization experiments indicate that the CMUT-on-CMOS elements are uniform in frequency response and are similar to CMUTs simultaneously fabricated on standard silicon wafers without electronics integration. Experiments on a 1.6-mm-diameter dual-ring CMUT array with a center frequency of 15 MHz show that both the CMUTs and the integrated CMOS electronics are fully functional. The SNR measurements indicate that the performance is adequate for imaging chronic total occlusions located 1 cm from the CMUT array.Yayın Coherent-array imaging using phased subarrays. Part I: Basic principles(IEEE-INST Electrical Electronics Engineers Inc, 2005-01) Johnson, Jeremy A.; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasThe front-end hardware complexity of a coherent array imaging system scales with the number of active array elements that are simultaneously used for transmission or reception of signals. Different imaging methods use different numbers of active channels and data collection strategies. Conventional full phased array (EPA) imaging produces the best image quality using all elements for both transmission and reception, and it has high front-end hardware complexity. In contrast, classical synthetic aperture (CSA) imaging only transmits on and receives from a single element at a time, minimizing the hardware complexity but achieving poor image quality. We propose a new coherent array imaging method-phased subarray (PSA) imagine-that performs partial transmit and receive beam-forming using a subset of adjacent elements at each firing step. This method reduces the number of active channels to the number of subarray elements; these channels are multiplexed across the full array and a reduced number of beams are acquired from each subarray. The low-resolution subarray images are laterally upsampled, interpolated, weighted, and coherently summed to form the final high-resolution PSA image. The PSA imaging reduces the complexity of the front-end hardware while achieving image quality approaching that of FPA imaging.Yayın Coherent array imaging using phased subarrays. Part II: Simulations and experimental results(IEEE-INST Electrical Electronics Engineers Inc, 2005-01) Johnson, Jeremy A.; Oralkan, Ömer; Ergün, Arif Sanlı; Demirci, Utkan; Karaman, Mustafa; Khuri-Yakub, Butrus ThomasThe basic principles and theory of phased subarray (PSA) imaging imaging provides the flexibility of reducing I he number of front-end hardware channels between that of classical synthetic aperture (CSA) imaging-which uses only one element per firing event-and full-phased array (FPA,) imaging-which uses all elements for each firing. The performance of PSA generally ranges between that obtained by CSA and FPA using the same array, and depends on the amount of hardware complexity reduction. For the work described in this paper, we performed FPA, CSA, and PSA imaging of a resolution phantom using both simulated and experimental data from a 3-MHz, 3.2-cm, 128-element capacitive micromachined ultrasound transducer (CMUT) array. The simulated system point responses in the spatial and frequency domains are presented as a means of studying the effects of signal bandwidth, reconstruction filter size, and subsampling rate on the PSA system performance. The PSA and FPA sector-scanned images were reconstructed using the wideband experimental data with 80% fractional bandwidth, with seven 32-element subarrays used for PSA imaging. The measurements on the experimental sector images indicate that, at the transmit focal zone, the PSA method provides a 10% improvement in the 6-dB lateral resolution, and the axial point resolution of PSA imaging is identical to that of FPA imaging. The signal-to-noise ratio (SNR) of PSA image was 58.3 dB, 4.9 dB below that of the FPA image, and the contrast-to-noise ratio (CNR) is reduced by 10%. The simulated and experimental test results presented in this paper validate theoretical expectations and illustrate the flexibility of PSA imaging as a way to exchange SNR and frame rate for simplified front-end hardware.Yayın Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging(IEEE, 2006-02) Değertekin, Fahrettin Levent; Güldiken, Rasim Oytun; Karaman, MustafaIn this study, a 64-element, 1.15-mm diameter annular-ring capacitive micromachined ultrasonic transducer (CMUT) array was characterized and used for forward-looking intravascular ultrasound (IVUS) imaging tests. The array was manufactured using low-temperature processes suitable for CMOS electronics integration oil a single chip. The measured radiation pattern of a 43 X 140- mu m(2) array element depicts a 40 degrees view angle for forward-looking imaging around a 15-MHz center frequency in agreement with theoretical models. Pulse-echo measurements show a -10-dB fractional bandwidth of 104% around 17 MHz for wire targets 2.5 mm away from the array in vegetable oil. For imaging and SNR measurements, RF A-scan data sets from various targets were collected using all interconnect scheme forming a 32-element array configuration. An experimental point spread function was obtained and compared with simulated and theoretical array responses, showing good agreement. Therefore, this study demonstrates that annular-ring CMUT arrays fabricated with CMOS-compatible processes are capable of forward-looking IVUS imaging, and the developed modeling tools can be used to design improved IVUS imaging arrays.












